摘要
在海安地电观测台站对地表、井下地电观测进行了对比实验,分析研究了地表游散电流、金属管线、以及人工交/直电流对地表、井下地电观测的影响.研究表明:(1)在使用铅电极的情况下,井下地电观测的长期稳定性明显优于地表观测;垂直方向观测的抗干扰能力明显优于地表、井下水平方向观测;(2)与地表观测相比,井下地电观测能在一定程度上抑制地表直流电流、雷电、和金属管线类的影响;(3)地表直流电流对地电观测所产生的干扰影响远大于交流电流.
Contrast experiment between the down-hole and ground-surface observations of the geo-electrical field and resistivity has been performed at Hai’an seismic station of Jiangsu province, and the effects for the geo-electrical observation accuracy that are caused by the ground-surface stray current,artificial A.C./D.C.and metal pipe net are analyzed and studied.As a result,we have the following results:(1)In the case of lead electrode,the long-term stability of the down-hole geo-electrical observation is superior to that of the ground-surface,and the vertical anti-interference ability is better than that of surface and the underground horizontal direction;(2)Compared with surface observations,underground Geo-electric observation can inhibit the effect of surface current,lightning,and metal pipeline class to a certain extent;(3)The interference generated by the surface of direct current is far greater than that of the alternating current to Geo-electric observation.
出处
《地球物理学进展》
CSCD
北大核心
2014年第4期1588-1596,共9页
Progress in Geophysics
基金
地震行业科研专项(200708017)
国家科技支撑计划课题(2006BAC01B02-04-03)共同资助
关键词
地电
观测
井下
地表
对比实验
geo-electric field and resistivity
observation
down-hole
ground surface
the contrast experiment