期刊文献+

几何布置对核料位测量性能影响的实验研究

Experimental Studies of the Effect of the Geometrical Arrangement on the Nuclear Level Measurement Performance
下载PDF
导出
摘要 为了研究几何布置对核料位测量工作性能的影响,并找出最佳的布置方式,分别对三种实验装置几何布置进行了实验模拟。结果表明,吸收法精确度最高,散射法次之,工作曲线法最差;从实验过程来看,吸收法和散射法需测多组数据才可得出料位位置;而工作曲线法,当作出工作曲线后,只需测一组数据,就可得出物料的料位位置,此方法更方便、简单和省时。 In order to study the effect of the geometric arrangements on the nuclear level measurement perform -ance and find out the best arrangement , the three experimental device geometrical arrangements were experi -mentally studied .The results indicate that the absorption method is of the highest accuracy , the second is the scattering method , the lowest is the working curve method .However , judging from the experimental process , the absorption and the scattering method need subgroup date , while the working curve method only need one set of date.So the working curve method is simple , quick and time-saving comparing with others .
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2014年第10期1222-1225,共4页 Nuclear Electronics & Detection Technology
关键词 几何布置 核料位测量 放射源 探测器 geometrical arrangement nuclear level measurement radioactive sources detector
  • 相关文献

参考文献6

二级参考文献18

  • 1贾胜铭,李念祖,李北城,洪汉德,邱兴禄,赵平海,孙普南.B-100型高压汽包水位在线保护计的二次仪表电子线路[J].核电子学与探测技术,1993,13(2):115-119. 被引量:1
  • 2李力源,王振中,管振海,宋卫东.核仪表中统计涨落对控制动作的影响及其消除措施[J].核电子学与探测技术,1993,13(2):87-91. 被引量:3
  • 3王国荣,黄兴滨,孙普男,杨大战,马永和.多路二线制料位计[J].核电子学与探测技术,2005,25(3):271-273. 被引量:1
  • 4黄步余,李丽华.SH3005-1999石油化工自动化仪表选型设计规范[S].北京:中围石油化工集团公司,1999.
  • 5Moe H J.辐射安全教程.北京:原子能出版社,1976.
  • 6中华人民共和国卫生部.GBZ125-2009含密封源仪表的放射源放射卫生防护要求[S].北京:人民卫生出版社,2009.
  • 7中华人民共和国质量监督检验检疫总局.GB18871-2002电离辐射防护与辐射源安全基本标准[S].北京:中国标准出版社,2003.
  • 8中国石化总公司.石油化工设备维护检修规程第七分册[M].北京:中国石化出版社,2012.
  • 9中华人民共和国建设部,中华人民共和国国家质量监督检验检疫总局.GB50093--2002自动化仪表工程施工及验收规范[s].北京:中国计划出版社,2003.
  • 10张秉海,王智.核料位计的工作原理及相关知识[J].石油化工自动化,2007,43(5):84-85. 被引量:17

共引文献42