调节熔断器电流的同时测量熔断器两端的电压,获得待测熔断器的U-I曲线并计算出U-R曲线,对比两种曲线分析了熔断机理和规律,发现当熔断器的U-I曲线开始偏离直线时表示其即将熔断,此时所对应的电流可以较准确地表征待测熔断器的实际熔断电流。U-I曲线检测方法简便并且对待测样品几乎无损,实验表明经过该法检测合格的熔断器可以更安全可靠地工作。
The U-I curve of the tested fuse was gained by measuring the voltage while changing the current through it and the U-R curve was further obtained by calculation. By comparing the two kinds of curves, the fusing mechanism was also analyzed. When the U-I curve begins to deviate from the straight line, the fuse would melt at that very current. The very current could also reflect the actual fusing current in a relatively accurate way. U-I curve test is a convenient method and causes no harm to the samples under test. The qualified fuse by this test could work more safely and reliably.
出处
《电子元件与材料》
CAS
CSCD
2015年第2期66-68,共3页
Electronic Components And Materials
基金
国家自然科学基金资助项目(No.51177151)
关键词
熔断器
电流保护
熔断电流
伏安曲线
可靠性
无损检测
fuse
current protection
fusing current
current-voltage curve
reliability
nondestructive testing