摘要
针对测量粒径的传统傅里叶测量系统(FS)的缺点,提出了一种改进的逆傅里叶激光测量系统(RFS)。通过实验测量,结果表明通过增加散射体与透镜的距离可以增加粒径测量的下限,扩大粒径测量的范围。另外,还对不同粒径的测量结果和理论计算结果进行了对比。结果表明,该方法特别适合于在小颗粒的测量。
For measurements on particle size, an improved reverse Fourier laser measurement system(RFS)which based on disadvantage traditional Fourier system(FS) is presented. In the experimental parts, the results show that the increase in lower limit of particle size measurement by increasing the distance of scattering volume and lens can expand the range of particle size measurement. In addition, the different particle size measurement results and theoretical calculation results are compared. The experimental evidence and simulation results show that, this method is especially suitable for measuring small particles.
出处
《激光与光电子学进展》
CSCD
北大核心
2015年第2期154-158,共5页
Laser & Optoelectronics Progress
基金
陕西省自然科学基础研究计划(2013JM8004)
陕西省自然科学基础研究计划(2014JQ8335)
关键词
测量
逆傅里叶光学
激光测量
粒径测量
MIE散射
measurement
reverse Fourier optics
laser measurement
particle size measurement
Mie scattering