摘要
目的:测定替诺福韦酯有机溶剂残留量。方法采用溶液进样法测定,检测器为 FID,色谱柱为 VF-17ms 毛细管柱,溶剂为二甲亚砜。结果乙醇、异丙醇、二氯甲烷、乙腈、乙酸乙酯、N,N-二甲基甲酰胺、氯甲基异丙基碳酸酯、N-甲基吡咯烷酮的相关系数均在0.9982~0.9997内,平均回收率在95.83%~106.59%范围内,RSD 在1.35%~3.22%范围内(n =9)。结论该方法准确、简单、快捷,适用于替诺福韦酯有机溶剂残留量的测定。
Objective To determine the residual organic volatile solvents Tenofov disoprox.Methods The samples were injected as solution with FID detector.The determination was performed on a VF-17ms GC column while dimethy sulfoxid was used as solvent.Re-sults The regression coefficients in ethyalcohol,iso-prophl alcohol,dichloromethane,acetonitrile,ethyl acetate,N,N-dimethyl for-mamide,chloro-methyl isopropyl carbonate,N-methyl-2-pyrrolodone were from 0.998 2 ~0.999 7.The recoveries were from 95.83% to 106.59%,with RSD from 1.35% to 3.22%(n =9)accordingly.Conclusions The method is simple,accurate and efficient,which can be used for the determination of Tenofov disoprox.
出处
《安徽医药》
CAS
2015年第1期50-52,共3页
Anhui Medical and Pharmaceutical Journal
关键词
气相色谱法
溶剂残留
gas chromatograph
residual organic volatile solvents