期刊文献+

满足通航标准条件下电站最小下泄流量计算与分析 被引量:2

Calculation and analysis of the minimum discharge about hydropower station under condition of satisfying navigation standard
下载PDF
导出
摘要 金沙江最下游梯级向家坝水电站已蓄水至正常蓄水位,但相关航运参数仍存在较大争议。为保障长江上游干线基本维护尺度,用保证频率法、保障航道基本维护尺度反推流量法、天然入汇比分配法等对金沙江向家坝水电站最小下泄流量进行研究分析,认为:在干支流均建电站的条件下,按照天然入汇比分配法较为合适;在不考虑非恒定流及河床冲刷影响的情况下,向家坝水电站最小下泄流量不应小于1 296 m3s。 Xiangjiaba hydropower station in Jinsha fiver has stored to normal level, but its shipping parameters is still a big controversy. To protect the upper carry out a research on the minimum discharge of Xiangj Yangtze River' s main basic maintenance dimensions, we iaba hydropower station in Jinsha fiver by the guaranteed frequency method, reverse flow method about waterway maintenance scale, natural inflow ratio with the score distribution method, etc. The result shows that the natural inflow ratio with the score distribution method is more suitable for hydropower station in branch streams, and the minimum discharge of Xiangjiaba hydropower station should not be less than 1 296 m^3/s.
作者 刘勇 张毅
出处 《水运工程》 北大核心 2015年第1期134-138,144,共6页 Port & Waterway Engineering
基金 国家科技支撑计划项目(2012BAB05B02)
关键词 最小下泄流量 入汇比 维护尺度 通航标准 the minimum discharge inflow ratio maintenance dimension navigation standard
  • 相关文献

参考文献6

  • 1GB50139-2004.内河通航标准[S].[S].,..
  • 2中国长江三峡集团公司向家坝指挥部.向家坝金沙江向家坝水电站水库运用和电站运行调度规程(试行)[S].
  • 3中国水电顾问集团中南勘测设计研究院,长江重庆航运工程勘察设计院.金沙江向家坝水电站升船机完建期航运调度方案[R].重庆:长江重庆航运工程勘察设计院,2013.
  • 4长江重庆航运工程勘察设计院.向家坝水电站运行下泄流量对长江叙渝段航道维护尺度影响研究[R].重庆:长江重庆航运工程勘察设计院,2013.
  • 5长江重庆航运工程勘察设计院.溪洛渡、向家坝水库蓄水及电站运行长江干线上游河段航道维护保障需求研究[R].重庆:长江重庆航运工程勘察设计院,2013.
  • 6中华人民共和国交通运输部.交通运输部办公室关于《金沙江向家坝水电站升船机完建期航运调度方案》的复函[厅水便[2013] 125号][Z] .北京:中华人民共和国交通运输部,2013.

共引文献151

同被引文献26

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部