摘要 为保障血液检测结果准确可靠,血液筛查实验室已建立了包括室内质量控制(QC)和室间质量评价(EQAS)在内的一系列质量控制技术。QC主要通过监测检测的精密度来确定实验室常规工作的可靠性,EQAS主要通过不同实验室间的比对,监测检测结果的准确性并发现实验室可能存在的偏差。QC和EQAS从不同方面监控检测质量,二者相辅相承,缺一不可,其结果和结论能为血液筛查结果准确可靠提供证据。 In order to keep blood testing results reliable, a series of quality control techniques, including internal quali- ty control (QC) and external quality assessment schemes (EQAS) have been established in blood screening laboratories. QC emphasizes on the precision of supervision to render routine testing reliable but EQAS inspects the accuracy of testing through comparing the testing results between different laboratories and finding the potential deviation in testing. QC and EQAS play ar im- portant role in maintaining testing quality through different aspects which complement each other to provide reliable testing resulths.
机构地区 上海市血液中心
出处 《中国输血杂志》 CAS CSCD 北大核心 2014年第12期1371-1373,共3页 Chinese Journal of Blood Transfusion
关键词 血液筛查 室内质量控制 室间质量评价 血站 internal quality control external quality assessment schemes blood screening
  • 相关文献

参考文献10

二级参考文献60

  • 1童清,王清涛.临床化学定量测定室间质量评价的有关问题[J].中华检验医学杂志,2005,28(2):131-133. 被引量:36
  • 2陈文祥,申子瑜,郭健,杨振华.临床检验量值溯源中的重要术语与概念及有关问题[J].中华检验医学杂志,2005,28(2):142-146. 被引量:35
  • 3郭健.临床化学定量测定室内质量控制及校准[J].医学检验与临床,2006,18(6):1-2. 被引量:3
  • 4范金城,胡峰.动态测量数据的抗扰性分析研究[J].数理统计与应用概率,1996,11(3):244-248. 被引量:25
  • 5中华人民共和国卫生部.血站实验室质量管理规范.2006-05-09.
  • 6Allain JP, Hewitt PE,Tedder, RS, et al. Evidence that anti-HBe but not HBV DNA testing may prevent some HBV transmission by transfusion. Br J Haematol, 1999,107 ( 1 ) : 186-195.
  • 7Soldan K, Barbara JA, Ramsay ME, et al. Estimation of the risk of hepatitis B virus, hepatitis C virus and human immunodeficiency virus infectious donations entering the blood supply in England. Vox. Sang, 2003,84 ( 4 ) : 274 -286.
  • 8Allain J-P. Occult hepatitis B virus infection:implications in transfusion. Vox Sang,2004,86 (2) :83-91.
  • 9Stramer SL, Glynm SA, Kleinman SH, et al. Detection of HIV-1 and HCV infections among antibody-negative blood donors by nucleic acid-amplification testing. N Engl J Med,2004,351 (8) :760-768.
  • 10Kleinman SH,Kuhns MC ,Todd DS,et al. Frequency of HBV DNA detection in US blood donors testing positive for the presence of anti-HBc:implications for transfusion transmission and donor screening. Transfusion,2003,43 (6) :696-704.