期刊文献+

制冷系统液体冷媒融霜与电热融霜的对比研究 被引量:11

Comparison study of liquid refrigerant defrosting and electric heating defrosting in refrigeration system
原文传递
导出
摘要 对冷库冷风机液体冷媒融霜和电热融霜过程中,库温的升高状况和能耗大小进行了实验研究。介绍了液体冷媒融霜实验原理和自动控制操作过程,电热融霜和液体冷媒融霜库温升高实验的装置和方法。对比分析实验结果,重点对库温升高状况和融霜能耗进行了分析研究,结果表明:液体冷媒融霜过程比电热融霜过程的库温升高约少10℃,在库房无负荷的条件下,液体冷媒融霜过程各工况库温平均升高几乎为零;液体冷媒融霜比电热融霜时间约长25min,能耗降低9%。 An experimental investigation was conducted to study the temperature increase of cold storage and the electricity consumption in the progress of liquid refrigerant defrosting and electric heating defrosting.The principle and automatic control process of liquid refrigerant defrosting was introduced,and the experiment device and method of liquid refrigerant defrosting was described.The comparison and analysis of the results of experimental were focused on the temperature increase of the cold storage and the electricity consumption.It is concluded that the temperature increase of the cold storage in the progress of liquid refrigerant defrosting is 10 ℃lower compared to the electric heating defrosting,and the average temperature rise is almost zero for each status in the process of the liquid refrigerant defrosting under the unloading condition in the cold storage.The liquid refrigerant defrosting time was 25 min longer than that of the electric heating defrosting,but electricity consumption of the liquid refrigerant defrosting decreases by 9%.
出处 《热科学与技术》 CAS CSCD 北大核心 2015年第1期40-44,共5页 Journal of Thermal Science and Technology
基金 天津市创新团队资助项目--食品冷链装置节能及储运新技术(TD12-5048)
关键词 电热融霜 液体冷媒融霜 融霜速率 融霜过程 electric heating defrosting liquid refrigerant defrosting defrosting rate defrosting process
  • 相关文献

参考文献8

二级参考文献22

  • 1史剑春.两种不同节流系统对融霜的影响[J].流体机械,1994,22(7):60-63. 被引量:6
  • 2臧润清,方筝,李景丽,温广.恒温恒湿机在结霜工况下运行的实验研究[J].低温工程,2005(3):60-64. 被引量:9
  • 3刘清江.冷库空气冷却器融霜节能的研究[J].制冷,2005,24(4):12-15. 被引量:17
  • 4庄友明.食品冷库除霜方法及其能耗分析[J].集美大学学报(自然科学版),2006,11(1):62-65. 被引量:21
  • 5Honghyun Cho,Yongchan Kim, Inkyu Jang. Performance of a showcase refrigeration system withmulti-evaporator during on-off cycling and hot-gas bypass defrost[J]. Energy, 2005, 30: 1915-1930.
  • 6Y Xia, Y Zhong, P S Hrnjak. Frost, defrost, and refrost and its impact on the air-side thermal-hydraulic performance of louvered-fin, flat-tube heat exchangers [J]. International Journal of Refrigeration, 2006, 29: 1066-1079.
  • 7Stoecker N, et al. Energy considerations in hot-gas defrosting of industrial refrigeration coils[C]. Final Report, ASHARE RP, 1983:189-193.
  • 8Coley M B .The cost of frost[J]. ASHARE Journal, 1983, 82 (9) : 29-31.
  • 9Cole R A. Refrigeration loads in a freezer due to hot gas defrost and their associated cast[J]. ASHARE Transactions, 1989, 95 (2) : 1149-1154.
  • 10[1]蒋汉文,邱信立.热力学原理与应用[M].上海:同济大学出版社,1990.

共引文献62

同被引文献79

引证文献11

二级引证文献41