期刊文献+

自动电位滴定法测定硼矿酸解液中的硼酸含量 被引量:9

Determination of boric acid in solution of acidulation process by automatic potentiometric titration
下载PDF
导出
摘要 采用自动电位滴定法测定硼矿酸解液中的硼酸含量。当硼酸质量为7.20~45.00 mg时,自动电位滴定法的测量相对误差小于1%,加标回收率为100.85%,比手工滴定法测量的准确度高。8次平行实验的相对标准偏差为0.18%,测量重复性较好。因此,用自动电位滴定法测定硼矿酸解液中的硼酸含量是可行的。 Determination of boric acid in the solution of acidulation process was carried out by automatic potentiometric titration. The automatic potentiometrie titration method was more accurate than the manual titration method with a relative error of less than 1% and a standard sample recovery rate of 100.85% when the mass of boric acid was at 7.20--45.00 mg.The relative standard deviation of 8 parallel determinations was 0.18% indicating a good reproducibility of the automatic potentiometric titration method.It was feasible to determine the content of boric acid by automatic potentiometric titration.
出处 《无机盐工业》 CAS 北大核心 2015年第2期60-61,66,共3页 Inorganic Chemicals Industry
基金 四川大学"大学生创新创业训炼计划"资助项目(20131134)
关键词 电位滴定 硼矿 酸解 硼酸 potentiometric titration boron acidulation boric acid
  • 相关文献

参考文献5

二级参考文献3

共引文献11

同被引文献118

引证文献9

二级引证文献12