摘要 以甲基对硫磷为模板分子,采用原位逐步聚合法制备了甲基对硫磷分子印迹聚合物,利用高锰酸钾-甲醛-甲基对硫磷化学发光体系,建立了测定甲基对硫磷高选择性的分子印迹-化学发光分析方法。方法的线性范围为2.0×10^(-6)~5.0×10^(-6)mol/L,检出限为2×10^(-7)mol/L,对1.0×10^(-6)mol/L甲基对硫磷溶液进行11次平行测定,相对标准偏差为3.3%。此法已用于谷物中甲基对硫磷的测定,结果满意。 Molecularly imprinted monolithic column was prepared using methyl parathion as the template molecule by in situ step-addition polymerization.A new chemiluminescence method for the determination of methyl parathion was proposed by the combination of methyl parathion-imprinted polymer and KMnO4- methyl parathion-formaldehyde-CL system.The linear range was 2.0×10^-6-5.0×10^-6 mol/L,the detection limit was 2.0× 10^-7 mol/L,the relative standard deviation was 3.3%(n=11).This method has been successfully applied to the determination of trace residue of parathion in vegetable and grain samples.
出处 《分析仪器》 CAS 2015年第1期35-37,共3页 Analytical Instrumentation
基金 重庆市大学生创新创业训练项目(201310637011) 国家自然基金项目(21267018) 青海省科技厅项目(2012-Z-903 2013-Z-502)资助
关键词 分子印迹 甲基对硫磷 化学发光 高锰酸钾 molecular imprinting methyl parathion chemiluminescence potassium permanganate
  • 相关文献

参考文献5

二级参考文献44

  • 1黄宝勇,欧阳喜辉,潘灿平.色谱法测定农产品中农药残留时的基质效应[J].农药学学报,2005,7(4):299-305. 被引量:97
  • 2赵海峰,王建华,邴欣,汝少国.蔬菜农药残留GC-MS分析方法改进与基质效应探讨[J].中国海洋大学学报(自然科学版),2006,36(1):76-80. 被引量:24
  • 3钱建亚.化学发光法在食品分析中的应用[J].食品与发酵工业,1997,23(3):69-74. 被引量:6
  • 4林旭聪,郭良洽.三唑磷-鲁米诺-H_2O_2发光体系的研究与应用[J].光谱实验室,2007,24(4):729-734. 被引量:1
  • 5POOLE C F. Matrix-induced response enhancement in pesticide residue analysis by gas chromatography [ J ]. J Chromatogr: A, 2007, 1158(1/2): 241-250.
  • 6ERNEY D R, GILLESPIE A M, GIVYDIS D M. Explanation of the matrix-induced chromatographic response enhancement of organophosphorus pesticides during open tubular column gas chromatography[ J]. J Chromatogr: A, 1993, 638 (1) : 57 -63.
  • 7CARSON L J. Modified storherr method for determination of organophosphorus pesticides in nonfatty food total diet composites[J]. JAOAC, 1981, 64(3): 714 -719.
  • 8MALLET C, MALLET V N. Conversion of a conventional packed-column gas chromatograph to accommodate megabore columns: Ⅱ. Determination of organophosphorus pesticides in environmental water[J]. J Chromatogr: A, 1989, 481: 37 -44.
  • 9STAN H J, GOEBEL H. Evaluation of automated splitless and manual on-column injection techniques using capillary gas chromatography for pesticide residue analysis[ J]. J Chromatogr: A, 1984, 314:413 -420.
  • 10STAN H J, GOEBEL H. Automated capillary gas chromatographic analysis of pesticide residues in food [ J ]. J Chromatogr: A, 1983, 268(1): 55-69.

共引文献99

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部