摘要 对330 MW火力发电机组主蒸汽流量、给水流量计量存在的偏差进行分析,采取修改主蒸汽流量函数、对给水流量进行温度修正等措施,消除了偏差,提高了机组节能降耗水平。 The measurement deviations of the main steam flow and the feed water flow of a 330 MW thermal power unit were analyzed. The main steam flow function was amended,and the temperature correction was done for the feed water flow. The deviations were eliminated,and the unit performance in energy saving and consumption reducing was improved.
作者 杨锐涵
出处 《华电技术》 CAS 2015年第1期47-48,78,共2页 HUADIAN TECHNOLOGY
关键词 给水流量 主蒸汽流量 偏差 温度修正 feed water flow main steam flow deviation temperature correction