期刊文献+

凝结水泵耗电率分析及优化改造 被引量:4

Analysis on power consumption rate of condensate pump and optimization reformation
下载PDF
导出
摘要 介绍华电国际电力股份有限公司所属火电厂凝结水泵耗电率偏高的问题,统计了5个级别机组凝结水泵耗电率的实际状况,查找了凝结水泵耗电率偏高的原因,采取了运行优化和变频改造等措施,取得了良好的效果。 The problem about high power consumption rate of condensate pumps in power plants of Huadian Power International Corporation Limited was introduced. The statistics of practical power consumption rate of condensate pumps of five classes of power units were given. The reasons of high power consumption rate of the condensate pumps were found. The measures of operation optimization and frequency conversion renovation were adopted,and favorable result was obtained.
作者 宗绪东
出处 《华电技术》 CAS 2015年第1期71-72,75,共3页 HUADIAN TECHNOLOGY
关键词 凝结水泵 耗电率 变频调速 优化改造 condensate pump power consumption rate variable frequency speed regulation optimization reformation
  • 相关文献

参考文献1

二级参考文献18

  • 1XU X, DE DONKER R W. A stator flux oriented induction motor drive[ J ]. Conf Rec IEEE/PESC, 1988,2:870 - 876.
  • 2GIUSEPPE GUIDI, HIDETOSHI UMIDA.A novel resistance estimation method for speed-sensorless induction motor drives[J].Transactions on Industry Application IEEE,2000,36(6):1619-1627
  • 3COLIN SCHAUDER. Adaptive speed identification for vector control of induction motors without rotational transducers[A].In Conf Rec IEEE-IAS Annu Meeting[C]. San Diego: IEEE Press, 1989.493-499.
  • 4FUJITA K. Instantaneous speed detection with parameter identification for AC servo systems[ J ]. IEEE Trans Industry Applications, 1992,28(4) :234 - 237.
  • 5BOSE B K. High performance control and estimation in ac drives control and Instrumentation[ J ]. IEEE Ind Applicat,1997,2:377 - 385.
  • 6YAMADA T, MATSUSE K, TSUKAKOSHI M,et al. A determining method of flux level for deadbeat flux level controlled direct field oriented induction motors using adaptive flux observer[ A ].Proc IECON'94[C]. Bologna: IEEE Press, 1994. 282- 292.
  • 7WASYNCZUK O, SUDHOFF S D. A maximum torque per ampere control strategy for induction motor drives[ J ].IEEE Tram Energy Conversion,1998,2:163 - 169.
  • 8KIM S H, SUL S K. Voltage control strategy for maximum torque operation for induction machine in the field weakening region[ J ]. IEEE Trails Ind Power Electron, 1998,1: 134- 141.
  • 9ZHANG CHENGHUI. Design and application of nonlinear feedback control system for SPWM inverter fed induction motor drive[A]. Li Botian.Proceedings of The IEEE International Conference on Industrial Technology[C].Guangzhou: South China University of Technology Press, 1994. 524- 527.
  • 10LOWERY THOMAS F, PETRO DAVID W. Application considerations for PWM inverter-fed low-voltage induction motors[J].IEEE Trans Ind Applicat, 1994,30(2) :286 - 293.