期刊文献+

Intercomparison of Environmental Gamma doses Measured with A NaI(Tl) Survey Meter and Thermoluminescent Dosimeters(TLDs) in the Poonch Division of Azad Kashmir, Pakistan

Intercomparison of Environmental Gamma doses Measured with A NaI(Tl) Survey Meter and Thermoluminescent Dosimeters(TLDs) in the Poonch Division of Azad Kashmir, Pakistan
下载PDF
导出
摘要 This study presents the intercomparison of the outdoor environmental gamma dose rates measured using a Nal (TI) based survey meter along with thermoluminescent dosimeters (TLDs) and estimation of excess lifetime cancer risk (ELCR), for the inhabitants of Poonch division of the Azad Kashmir, Pakistan. CaF2: Dy (TLD-200) card dosimeters were installed at height of 1 m from ground at fifteen different locations covering the entire Poonch division comprising of three districts. This study presents the intercomparison of the outdoor environmental gamma dose rates measured using a Nal (TI) based survey meter along with thermoluminescent dosimeters (TLDs) and estimation of excess lifetime cancer risk (ELCR), for the inhabitants of Poonch division of the Azad Kashmir, Pakistan. CaF2: Dy (TLD-200) card dosimeters were installed at height of 1 m from ground at fifteen different locations covering the entire Poonch division comprising of three districts.
出处 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第12期969-972,共4页 生物医学与环境科学(英文版)
  • 相关文献

参考文献10

  • 1Simpkins RW, Kearfott KJ. The Minimum number of observations necessary to develop an average thermoluminescent dosimeter element correction factor.Radiat Prot Manag, 1997; 13, 55-61.
  • 2Harvey JA, Haverland NP, Kearfott KJ. Characterization of the glow peak fading properties of six common thermolumin- escent materials. App Radiat Isot, 2010; 68, 1988-2000.
  • 3Harvey JA, Kearfott KJ. Reproducibility of glow peak fading characteristics of thermoluminescent dosimeters. Radiat Meas, 2011; 46, 319-22.
  • 4Harvey JA, Kearfott KJ. Effects of high ambient temperature on glow-peak fading properties of LiF: Mg, Ti thermoluminescent dosemeters. Radiat Prot Dosim, 2012; 149, 109-15.
  • 5Harvey JA, Thomas EM, Kearfott KJ. Quantification of various factors influencing the accuracy and precision of thermoluminescent detector calibrations for new and used chip sets. Health Phys, 2011; 100,S79-S91.
  • 6Rafique M. Ambient indoor/outdoor gamma radiation dose rates in the city and at high altitudes of Muzaffarabad (Azact Kashmir). Environ Earth Sci, 2013; 70, 1783-90.
  • 7Rafique M, Basharat M, Azhar SR, et al. Effect of geology and altitude on ambient outdoor gamma dose rates in district poonch, Azad Kashmir. Carpath J Earth Env, 2013; 8, 165-73.
  • 8UNSCEAR. Ionizing radiation: Sources and biological effects, report to the general assembly with scientific annexes, United Nations, New York, 2000.
  • 9Worldstat info, http://en.worldstat.info/Asia/Pakistan, [2014-03-17].
  • 10Recommendations of the ICRP. Annals of the ICRP, 1990, 21, Publication 60.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部