结合相关规范,利用通用有限元软件ADINA对季节性冻土区不设置保温层与铺设保温苯板下的渠道温度场进行了数值模拟对比分析。结果表面:铺设保温苯板后的渠道,不仅苯板下温度已为正温,而且冻胀量相对于未设置苯板的渠道明显减小,充分说明保温法对于渠道抗冻胀是一种有效的措施。
By combining the relevant specification ,this paper used the universal finite element software ADINA to do numerical simulation analysis about channel temperature field in seasonal frozen regions without insulating layer and with insulation ben-zene board .The result shows that not only the benzene board temperature is positive ,but also its frost heave is obviously re-duced ,this fully shows that the heat preservation method is an effective measure .
出处
《杨凌职业技术学院学报》
2014年第4期4-6,10,共4页
Journal of Yangling Vocational & Technical College
基金
陕西省农业科技创新项目(2011NXC01-20)
杨凌职业技术学院科学研究项目(A2014019)
关键词
梯形渠道
混凝土衬砌
冻胀破坏
苯板
the trapezoidal channel
lining concrete
frost heaving damage
benzene board