期刊文献+

基于Smith预估器的PCR仪时滞温控系统 被引量:7

Time-delay Control System of PCR Instrument Based on Smith Predictor
下载PDF
导出
摘要 为了解决聚合酶链式反应(PCR)仪温度控制中的纯滞后问题,在试验数据的基础上,基于Matlab搭建仿真模型.仿真结果表明,加入Smith预估补偿环节可以较好地解决纯滞后效应带来的积分累积问题.将仿真得到的方法移植到实际的控制中,可获得良好的控制效果.最后提出添加一个比例-积分-微分(PID)控制器的改进算法,用以解决Smith预估控制算法中鲁棒性不强的问题. In order to solve the pure time delay problem of temperature control in polymerase chain reaction (PCR) apparatus,a Matlab simulation model was built based on actual experiment data.The simulation results show that the temperature control system with the Smith predictor loop can reduce the accumulated error in integrated loop,which is caused by the pure time delay.The actual PCR apparatus can get a better temperature control effect with the method concluded from the simulation model.Finally,an optimized algorithm of proportion-integration-division (PID) controller was proposed to improve the robustness of the Smith predictor.
出处 《同济大学学报(自然科学版)》 EI CAS CSCD 北大核心 2015年第2期293-298,共6页 Journal of Tongji University:Natural Science
关键词 聚合酶链式反应(PCR)仪 Smith预估 温度控制 纯滞后 polymerase chain reaction (PCR) equipment Smith predictor temperature control pure lag
  • 相关文献

参考文献2

  • 1PAN Aixian,ZHAO Weihua,ZHANG Min.Temperaturecontrol algorithm design of the PCR instrument[C]∥Wireless Communications,Networking and Mobile Computing.Wuhan:Scientific Research Publishing,2008:1-4.
  • 2LIU Bin,GUO Lingling,DENG Yan,et al.Research of temperature control algorithm in PCR gene amplify instrument[C]∥Proceeding of 2011 International Symposium on Bioelectronics and Bioinformatics(ISBB),International Symposium.Piscataway,NJ:IEEE,2011:119-122.

同被引文献55

引证文献7

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部