应用千伏级锥形束CT对宫颈癌调强放疗过程中摆位误差分析 被引量:3

下载PDF
导出
摘要 目的:应用千伏级锥形束CT(CBCT)分析宫颈癌调强放射治疗过程中的摆位误差。方法随机选取18例宫颈癌患者治疗前行CBCT扫描,每周1次。获得在左右(X)、头脚(Y)、腹背(Z)方向上的误差值。结果在X、Y、Z方向上总体误差分别为(1.64±2.16)mm、(2.92±3.60)mm、(1.57±1.85)mm;摆位误差的绝对值在X方向上94.3%≤5 mm、Y方向上89.8%≤5 mm、Z方向上93.2%≤5 mm。结论采用CBCT技术在宫颈癌调强放射治疗过程中能有效地对摆位误差进行实时验证,并为靶区的外放范围提供参考,从而为临床提供质量保证。
出处 《中国血液流变学杂志》 CAS 2014年第2期342-343,346,共3页 Chinese Journal of Hemorheology
  • 相关文献

参考文献5

  • 1Mell LK, Roeske JC, Mundt AJ. A survey of intensity- modulated radiation therapy use in the United States[J]. Cancer, 2003, 98(1): 204 - 211.
  • 2Hansen EK, Larson DA, Aubin M, et al. Image-guided radiotherapy using megavoltage cone-beam computed tomography for treatment of paraspinous tumors in the presence of orthopedic hardware[J]. Int J Radiat Oncol Biol Phys, 2006, 66(2): 323 - 326.
  • 3于龙珍,翟振宇,沈君姝.体部肿瘤精确放疗摆位误差分析[J].中国医学物理学杂志,2007,24(3):160-162. 被引量:36
  • 4胡逸民.放射治疗的质量保证与质量控制[A].见:殷蔚伯,余子豪,徐国镇,等主编肿瘤放射治疗学[M].第4版.北京:中国协和医科大学出版社,2008.207-208.
  • 5ICRU. ICRU Report No 24. Determination of absorbed dose in a patient irradiated by beams of X or Gamma rays in radiotherapy procedures[S]. 1976.

二级参考文献8

  • 1Uematsu M,Akira S,Kazuhiko T,et al..Focal,high dose,and fractionated modified stereotactic radiationtherapy for lung carcinoma patients[J].Cancer,1998,82:1062-1070.
  • 2MeertensH,BijholdJ,StrackeeJ.A method of the measurement of field placement errors in digital portal images[J].Phys Med Biol,1990,35:299-323.
  • 3Hurkmans C W,Remeijer P,Lebesque J V,et al.Set-up verification using portal imaging; review of current clinical practice[J].Radiather Oncol,2001,58(2):105-120.
  • 4Hans CJ,John R.Analysis and reduction of 3D systematic and random setup deviations during the simulation and treatment of lung cancer patients with CT based external beam radiotherapy dose planning[J].Int Radiat Oncol Biol Phys,2001,49:857-868.
  • 5Lax I,Blomgren H,Naslund I,et al.S tereotactic radiotherapy of malignacies in the abdomen[J].Acta Oncologia,1994,33:677-703.
  • 6Onishi H,Kuriyama K,Komiyama T,et al.CT evaluation of patient deep inspiration self-breath-holding:how precisely can patients reproduce the tumor position in the absence of respiratory monitoring devices?Med Phys[J].2003,30(6):1183-1187.
  • 7Balter JM,Ten-Haken RK,Lawrence TS,et al.Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing[J].Int Radiat Oncol Biol Phys,1996,36:167-174.
  • 8戴建荣,胡逸民.电子射野影像系统[J].中国医学物理学杂志,1999,16(4):204-208. 被引量:26

共引文献35