摘要 设计一种基于出风温湿度检测的冷却塔防白雾控制装置,该装置可实现出风温湿度参数的实时采集,并进行相应计算,根据计算结果判断冷却塔是否处于雾区,从而实现防白雾水泵的自动变压控制,利用电动阀控制最大进水量,实现较小混水量的消雾,节约成本。 In this paper, a device of anti-mist cooling tower based on detection of air temperature and humidity was designed. This device can realize real-time acquisition of wind temperature and humidity parameters, using the corresponding calculation of wind temperature and humidity parameters, according to the calculation results to determine whether a cooling tower in fog area, so as to realize the automatic pressure control of white mist pump, using electric valve control into the biggest water, achieve smaller mix water fog dispersal, cost savings. The device is practical, applicable to all wet cooling tower, cooling tower can be used to automatically remove the transition season of white mist.
出处 《自动化与信息工程》 2014年第5期16-18,22,共4页 Automation & Information Engineering
基金 广东省科技型中小企业技术创新专项项目(2012CY166)
关键词 冷却塔 防白雾 出风温湿度 Cooling Tower Anti-Mist Air Temperature and Humidity
  • 相关文献

参考文献8

  • 1金深洋,金惠珍,夏再忠,陈传涓,陆紫生.白雾防止型密闭式喷淋冷却塔试验研究[J].工业用水与废水,2010,41(4):72-74. 被引量:4
  • 2朱文杰.湿式冷却塔白烟现象分析与解决方案[J].制冷空调与电力机械,2010,31(4):20-23. 被引量:21
  • 3Koening L R, Anomalous snowfall caused by natural-draft cooling towers[J]. Atmospheric Environment, 1981, 15(7): 1117-1128.
  • 4Kramer M L, Seymour D E, Butler M J, et al. Cooling tower flight program data December 1974-March 1975, by Smith/Singer Meteorologists[R]. NewYork: Inc Amityville, N.Y. for American Electric Power Service Coep. OH., 1975.
  • 5Orville H D, Hirsch J H ,May L E. Application of a cloud model to cooling tower plumes and clouds[J]. Journal Applied Meteor, 1980,19(11): 1260-1272.
  • 6Policastro A J, Dunn W E, Carhart R A. A model for seasonal and annual cooling tower impacts[J]. Atmospheric Environment, 1994, 28(3): 379-395.
  • 7刘桂雄,叶季衡,肖若,洪晓斌,谭小卫.冷却塔热力性能在线监测装置及系统研制[J].中国测试,2013,39(4):64-68. 被引量:8
  • 8谭小卫.一种基于出风温湿度检测的冷却塔防白雾控制装置[P].中国:ZL201220317582.2013-02-20.

二级参考文献21

  • 1吴建国,张培建,瞿国庆,陆平.基于特征模型的冷却塔监控装置设计[J].电力自动化设备,2006,26(10):67-69. 被引量:1
  • 2赵振国.冷却塔[M].第一版.北京:中国水利水电出版社,1996.248-287.
  • 3唐韵,夏再忠,王如竹.冷却塔白烟防止技术[A].制冷空调新技术进展-第四届全国制冷空调新技术研讨会论文集[C].2006.
  • 4Policastro A J,Dunn W E,Carhart R A.A model for seasonal and annual cooling tower impacts[J].Atmospheric Environment,1994,28(3):379-395.
  • 5Koenig L R.Anomalous snowfall caused by natural-draft cooling towers[J].Atmospheric Environment,1981,15(7):1117-1128.
  • 6Kramer M L,D E Seymour,M J Butler,et al.Cooling tower flight program data December 1974-March 1975,by Smith/Singer Meteorolngists[R].New York:Ine Amityville,N.Y.for American Electric Power Service Coep.OH,1975.
  • 7Orville H D,Hirsch J H,May L E.Application of a cloud model to cooling tower plumes and clouds[J].Journal Applied Meteor,1980,19(11):1260-1272.
  • 8唐韵.低下冷却器的紧凑性及防白雾研究[D].上海:上海交通大学,2007.
  • 9Panjeshahia M H, Ataei A, Gharaie R, et al. Optimum design of cooling water systems for energy and water' conservation[J]. Chemical Engineering Research and De- sign, 2009(87 ) : 200-209.
  • 10Merkel F. Verdunstungskuhlang[D]. Berlin:VDI Forschun gsarbeiten, 1925: 12-28.