期刊文献+

高效液相色谱法测定复方消毒剂中聚六亚甲基双胍准确性研究 被引量:6

Study on accuracy of polyhexamethylene biguanide in compound disinfectant by high performance liquid chromatography
原文传递
导出
摘要 目的建立复方消毒剂中聚六亚甲基双胍测定方法。方法采用气体熏蒸载体杀菌试验方法,对机器发生二氧化氯气体杀灭枯草芽孢杆菌黑色变种芽孢高效液相色谱法,对复方消毒剂中聚六亚甲基胍含量测定的准确性和稳定性进行评价。结果用高效液相色谱法检测聚六亚甲基胍含量在5~100 mg/L范围内线性良好。相关系数r=0.9997,回收率为97.8%~100.1%,RSD=1.0%~1.3%,检出限为0.15 mg/L,定量限为0.5 mg/L。结论用高效液相色谱法检测复方消毒剂中聚六亚甲基双胍含量,操作简便、快速准确,可满足日常检测。 Objective To develop the method for determination of Polyhexamethylene biguanide in disinfectants. Methods High performance liquid chromatography was used to evaluate the accuracy and stability for determination of Polyhexam- ethylene biguanide in eompound chemical disinfeetant. Results The calibration curve was linear in the range of 5 - 100 mg/L with the correlation coefficient (r) of 0. 9997, and the recoveries were from 97. 8% to 100. 1% , with the rela- tive standard deviations in the range of 1.0% to 1.3% , the limit of detection was 0. 15 mg/L(S/N =3) , and the limit of quantification was 0. 5 mg/L Conclusion High performance liquid chromatography method is simple, reliable, accurate and available for determination of the Polyhexamethylene biguanide in disinfectants.
出处 《中国消毒学杂志》 CAS 北大核心 2015年第1期10-12,共3页 Chinese Journal of Disinfection
关键词 聚六亚甲基双胍 高效液相色谱法 复方消毒剂 含量检测 polyhexamethylene biguanide high pe^Cormance liquid chromatography( HPLC ) compound disinfectants content detection
  • 相关文献

参考文献12

二级参考文献26

  • 1陈璐,赵克义,袁青春,温宪芹,孙启华.一种即时净手液性能的试验观察[J].中国消毒学杂志,2004,21(3):208-210. 被引量:12
  • 2黄新宇.盐酸聚六亚甲基胍消毒剂研究进展[J].中国卫生工程学,2005,4(5):324-325. 被引量:30
  • 3崔玉杰,郭金铭,刘继敏,孙路.一种手消毒液杀菌效果及毒性试验观察[J].中国消毒学杂志,2006,23(2):138-140. 被引量:7
  • 4ROSIN M, WELK A, BERNHARDT O, et al. Effect of a polyhexamethylene biguanide mouthrinse on bacterial counts and plaque [ J ]. Journal of Clinical Periodontology, 2001,28(12) : 1121 -1126.
  • 5WELK A, SPLIETH C H, SCHMIDT M G, et al. The effect of a polyhexamethylene biguanide mouthrinse compared with a triclosan rinse and a chlorhexidine rinse on bacterial counts and 4 - day plaquere - growth [ J ]. Journal of Clinical Periodontology, 2005,32(5 ) :499- 505.
  • 6COLLINS A N, BOTHWELL B D, MCPHERSON G J. Antimicrobial polymer: U S, 6706855 [ P]. 2004.
  • 7TOSHIAKI H, YASUKO N, RYO K. Determination of biguanide groups in polyhexamethylene biguanide hydrochloride by titrimetrie methods [ J ]. Analytical Sciences, 2003, 19 : 1525 - 1528.
  • 8[1]薛广波主编.现代消毒学.第1版.北京:人民卫生出版社,1999:21-67.
  • 9[3]Russell AD, Hugo W B. Ayliffe GAJ Principles and Practice of Disinfection Blackwell Science, 1999:284-375.
  • 10[5]Ballantye B. Influence of alkalinization of glutaraldehyde biocidalsolutions on acute toxicity primary irritancy and skin sensitazition. Vet, Hum.-Toxicol, 1997,39(6) :340-346.