期刊文献+

铋膜修饰FTO导电玻璃电极检测溶液中的铅离子 被引量:1

Bismuth modified FTO conducting glass electrode for detection of lead ion
下载PDF
导出
摘要 利用铋膜修饰FTO导电玻璃电极,通过阳极溶出伏安法测定溶液中痕量铅离子,考察并优化测定铅离子的工艺参数。在0.1mol/L HAc-NaAc缓冲溶液(pH=5.0)中,沉积电位在-1.0V搅拌富集360s,铅离子在铋膜修饰FTO导电玻璃电极上可得到最高溶出电流。铅离子标准曲线线性范围为50~250μg/L,最低检出限为2.35μg/L。铋膜修饰FTO导电玻璃电极可对铅离子进行检测,而且检测结果良好。 Modification of FTO glass electrode with bismuth was carried out to detect trace lead ion(Pb2+)in aqueous solution by the anodic stripping voltammetry.When electrochemical accumulation step was fixed at-1.0Vin 0.1mol/L HAc-NaAc buffer solution(pH =5.0)for 360 s,the highest stripping current of Pb2+can be obtained.The stripping currents increased linearly with increase of Pb2+concentrations in the range 50-250μg/L.The limit of detection(LOD)of Pb2+was 2.35μg/L.The results suggested that Pb2+in aqueous solution could be detected by bismuth modified FTO glass electrode.
出处 《大连工业大学学报》 CAS 北大核心 2015年第1期34-36,共3页 Journal of Dalian Polytechnic University
基金 辽宁省高校重大科技平台项目(2011191)
关键词 FTO导电玻璃 铋膜电极 差分脉冲伏安法 溶出峰 FTO conductive glass bismuth film electrode differential pulse voltammetry stripping peak