期刊文献+

The ECT System for RAON'S Cavities

The ECT System for RAON'S Cavities
下载PDF
导出
摘要 The ECT (eddy current test) system is in use for Nb surface quality control in many laboratories. This system can inspect Nb surthce quickly using high resolution probe. The ECT system for RAON's cavity was made with these features: it has a 3-axis acting probe movenlent system, it can inspect a big size of Nb sheet, which is 1,200 mm × 365 mm and it contains the analysis program that can show the result as a 2D and 3D images as well as the relative figure of the surface level. The standard sample was made with various sizes of defects using the same Nb sheet that was used to make RISP (Rare Isotope Science Project) cavity. The ECT system conditioning was carried out to optimize the ECT operation on the frequency of which the range is from 300 KHZ to 2 MHz. The result of 900 KHZ showed the strongest signal. The conditioning experiment on other parameter will be carried out in the near future.
出处 《Journal of Mechanics Engineering and Automation》 2015年第1期53-57,共5页 机械工程与自动化(英文版)
关键词 SRF (superconducting radio frequency) cavity eddy current NON-DESTRUCTIVE NIOBIUM ECT system ECT系统 表面质量控制 涡流探伤 高解析度 nt系统 3D图像 标准样品 系统调节
  • 相关文献

参考文献12

  • 1Singer, W., Proch, D., and Brinkmann, A. 1997. "Diagnostic of Defects in High Purity Niobium." Presented at the Workshop on RF Superconductivity, Abano Terme (Padova), Italy.
  • 2lwashita, Y., Fuwa, Y., Hashida, M., Otani, K., Sakabe, S., Tokita, S., and Tongu, H. 2012. "Non-destructive Inspection for SC Cavities." Presented at LINAC 2012, Tel-Aviv, Israel.
  • 3lwashita, Y., Tongu, H., Hayano, H., and Saeki, T. 2011. "Updates on R & D of Nondestructive Inspection Systems for SRF Cavities." Presented at SRF 2011, Chicago.
  • 4Brinkmann, A., and Singer, W. 2008. "Nondestructive Testing of Niobium Sheets for SRF Cavities Using Eddy-Current and Squid Detection." Presented at LINAC 2008, Victoria, BC, Canada.
  • 5Brinkmann, A., Lengkeit, M., Singer, X., and Singer, W. 2010. "Testing of Niobium Material for the European XFEL Pre-series Production." Presented at LINAC 2010,Tsukuba, Japan.
  • 6Brinkmann, A., Arnold, S., Ermakov, A., Iversen, J., Lengkeit, M., POrschmann, A., Sch~ifer, L., Singer, W., and Singer, X. 2013. "Statistic to Eddy-Current Scanning of Niobium Sheets for the European XFEL." Presented at SRF 2013, Paris, France.
  • 7lwashita, Y., Fujisawa, H., Tongu, H., Hayano, H., Watanabe, K., and Yamamoto, Y. 2009. "R & D of Nondestructive Inspection Systems for SRF Cavities." Presented at SRF 2009, Berlin, Germany.
  • 8Boffo, C., Bauer, P., Foley, M., Brinkmann, A., and Ozelis, J. "Eddy Current Scanning at Germilab." Newport News, USA.
  • 9Boflb, C., Bauer, P., Foley, M., Antoine, C., Cooper, C., and Brinkmann, A. 2007. "Eddy Current Scanning of Niobium for SRF Cavities at Fermilab." 1EEE Transactions on Applied Superconductivity 17 (2): 1326-9.
  • 10Jeon, D. O. 2013. "Status of the RAON Accelerator Systems." Presented at IPAC2013, Shanghai, China.