期刊文献+

接触网线岔弓网故障的原因及预防措施 被引量:1

Causes and Preventions of Faults of Pantograph and OCS at Cross Over of OCS
下载PDF
导出
摘要 通过对正线与侧线、侧线与侧线交叉线岔发生弓网故障的原因进行了分析,提出了防止交叉线岔发生弓网故障的预防措施:始触区内不可安装任何线夹;采用双腕臂;采用交叉吊弦;确保导线相对高度;防止电力机车钻弓;进行包络线检查;防止防串中锚发生串动等。 By analysis of causes of faults of pantograph and OCS at cross over between mainline and siding line and between two siding lines, it raises the preventive measures for faults of pantograph and OCS at cross over: no installing the clamp in the beginning of the contact areas; adopting the double cantilevers; adopting the crossed droppers;guarantee the relative height of the conductor; prevention of incorrect running of the pantograph of the electriclocomotive; implementation of inspection of the envelop lines; prevention of the motion of the mid-point anchor etc.
出处 《电气化铁道》 2002年第3期21-22,共2页 Electric Railway
关键词 接触网线岔 接触网 弓网故障 原因分析 电气化铁路 Cross over of OCS faults of pantograph and OCS causes preventive measures