摘要
以国产600M W低压转子为研究对象,建模并对系统进行了动力学特性计算,获得了两种支承条件下的转子动态特性数据,并进行了对比分析,得出了辅助支承对转子系统的稳定性变化情况。
Dynamic characteristics of 600 MW domestic low-pressure rotor are discussed by building a dynamic model Thereafter, the unbalance response curve of the rotor is obtained and analyzed comparatively under condition of two different ancillary shorings. The influence of the ancillary shoring on the stability of rotor system is obtained.
出处
《机械工程师》
2014年第12期205-206,共2页
Mechanical Engineer
关键词
汽轮机转子
辅助支承
系统稳定性
steamturbin rotor
ancillary shoring