摘要
对机房集中监控系统三级监控单元SU、SC、SS所使用的各种物理设备的类型及其原理进行分析,提出有针对性的物理设备故障检测技术及日常维护方法。所探讨的这些故障检测技术及维护方法,均经过实践证明具有高准确度,可以为机房维护人员准确分析设备故障状态提供参考,及时有效地采取措施,提高工作效率和降低维护费用。
The types and principles of physical equipment used in the third level monitoring unit (SU, SC, SS) in centralized monitoring system in computer rooms are analyzed. Some fault detection technology as well as daily maintenance methods, which have been proved to have high accuracy, are given. With the methods mentioned in the paper, the maintenance workers can identify the state of the equipment failure accurately and take effective measures to improve work efficiency and lower maintenance cost.
出处
《计算机时代》
2015年第2期45-46,49,共3页
Computer Era
基金
云南省教育厅科学研究基金项目(2013C202)
关键词
监控系统
SU
SC
SS
检测
维护
maintaining centralized monitoring system
SU
SC
SS
detection
maintenance