摘要 分析了发电厂在线pH表准确度检验存在的问题,介绍了一种在线pH表准确度检验装置,以及装置所用碱化剂的选择,并利用该装置对Honeywell公司生产的UDA2182型在线pH表的检测准确度以及碱化剂稳定性进行了实验.结果表明,该装置可以提高在线pH表检验的可靠性和准确度. The problems with the accuracy test of the power plant pH meter are analyzed, and adevice for the accuracy test of the pH meter and the selection of basifier for the device isintroduced, and the precision of the UDA2182 online pH meter which is produced by Honeywellcompany as well as the stability of the basifier are tested through the utilization of such device. Theresults prove that using the device to test the accuracy of the power plant online pH meter canimprove its reliability and accuracy.
作者 刘伟 顾雷
出处 《上海电力学院学报》 CAS 2015年第1期45-48,共4页 Journal of Shanghai University of Electric Power
关键词 pH表 干扰因素 准确度检验 碱化剂 pH table interference factors accuracy test basifier
  • 相关文献

参考文献8

  • 1中华人民共和国国家发展和改革委员会.DL/T805.4-2004火电厂汽水化学导则[S].北京:中国电力出版社,2005.
  • 2中华人民共和国国家发展和改革委员会.DL/T5068-2006火力发电厂化学设计技术规程[S].北京:中国电力出版社,2006.
  • 3中华人民共和国国家能源局.DL/T677-2009发电厂在线化学仪表检验规程[S].北京:中国电力出版社,2009.
  • 4ASTM International. D5128 - 14 standard test methods for pH measurement of water of low conductivity S ]. West Conshohocken, PA, 2014.
  • 5VGB-R450Le.68bar以上蒸汽动力设备给水、炉水、蒸汽导则[S].德国,1995.
  • 6中华人民共和国国家能源局.DL/T1201-2013低电导率水PH在线测量方法[S].北京:中国电力出版社,2013.
  • 7傅献彩.物理化学[M].第5版.北京:高等教育出版社,2006:39-71.
  • 8刘玮,曹杰玉.提高电厂高纯水pH值测量准确度的研究[J].中国电力,2006,39(10):80-83. 被引量:17

二级参考文献5

  • 1GRAY D M.Upgrade you pH measurement in high-purity water[J].Power,1985 (3):95-96.
  • 2MCMILLAN G K.pH Measurement and control[M].Instrument Society of America,1994.
  • 3FILER S,ALISON V.Temperature compensation and reference electrode considerations for power plant high purity water pH[J].PowerPlant Chemistry,2002 (1):21-26.
  • 4GRAY D M,CAHOOE R A.Compensate you pH measurement for solution temperature[J].Power,1982 (7):56-57.
  • 5ALISON V.Temperature compensation and reference electrode considerations for power plant high purity water pH[J].PowerPlant Chemistry,2000,2(1):21-26.