摘要
依据第三届南方电网公司基建"金点奖"大赛绿色线路节能导线方案设计输入条件清单要求(220 kV为同塔双回、每回正常最大负荷305 MVA、海拔1 000 m^1 500 m、基本风速25 m/s(离地面10 m)、覆冰厚度10 mm,按山地行规划设计)进行分析论证。
This paper analyzed and demonstrated the transmission line energy-saving conductor project design input condition list requirement( 220 kV with common-tower double-transmission lines, each line normal maximum load of 305 MVA, altitude of 1 000-1 500 m, basic wind speed of 25 m/s( 10m from the ground), ice thickness of 10 ram, according to mountainous region guild regulations design) based on the third session of Southern Power Grid Company infrastructure" Jindian Award" competition.
出处
《贵州电力技术》
2015年第3期4-6,共3页
Guizhou Electric Power Technology
关键词
节能
导线
标准设计
杆塔
经济适用性
分析
energy-saving
conductor
standard design
tower economic applicability
analysis