氧化锌避雷器抗相间、空间干扰带电测试研究 被引量:8

Research on Interphase and Space Interference Electric Testing Technology for Zinc Oxide Lightning Arrester
下载PDF
导出
摘要 对变电站内氧化锌避雷器及其周围导体进行三维建模,直接仿真计算氧化锌避雷器遭受的相间、空间干扰电流的幅值和相位,评估干扰源对氧化锌避雷器带电测试的影响大小,并在已有氧化锌避雷器带电检测技术应用成果的基础上,通过叠加原理,将此干扰电流滤除以得到氧化锌避雷器绝缘状态的真实信息,提高避雷器带电测试水平,为逐步开展的状态检修工作提供可靠的数据支撑。 this topic proposed within the substation on zinc oxide lightning arrester and the surrounding the conductor for 3 d model-ing, and the direct simulation of the zinc oxide lightning arrester to suffer , space interference current amplitude and phase, to assess the effect of interference sources of zinc oxide lightning arrester charged test size, and results in the existing zinc oxide lightning ar-rester charged detection technology application, on the basis of through the superposition principle, the interference current filter di-vided by zinc oxide lightning arrester insulation condition of real information , improve the level of lightning arrester charged test, to gradually develop the status of the repair work to provide reliable data to support.
作者 高树功 沈映
出处 《云南电力技术》 2014年第6期15-18,共4页 Yunnan Electric Power
关键词 氧化锌避雷器 三维建模 仿真计算 相间空间干扰 幅值和相位 zinc oxide lightning arrester 3D modeling simulation calculation interphase and space interference amplitude and phase
  • 相关文献

参考文献2

  • 1GB11032-2000.交流无间隙金属氧化物避雷器[S].[S].,..
  • 2Q/CSG114002-2011.电力设备预防性试验规程[z].

共引文献30

同被引文献87

引证文献8

二级引证文献20