船舶交流电网在线绝缘监测装置研究 被引量:6

Research of online insulation monitoring system for the power system of ship
下载PDF
导出
摘要 随着中国经济的飞速增长,航运行业也得到蓬勃发展。而随着船舶的大型化,自身电力系统容量越来越大,电网也越加密集,并且船舶航行也不是在稳定环境下进行,海水侵蚀比较严重,从而电力系统的绝缘故障频率较高,对绝缘故障点的迅速定位就特别重要。本文在研究了现代绝缘监测系统技术基础上,提出了一种单频信号绝缘监测技术,通过对传统双频信号监测技术的改进,简化了系统电路与软件复杂度。最后设计了基于DSP的在线监测系统装置,验证了系统的有效性。 With the rapid growth economy of china,shipping industry also has developed rapidly.With the ship become more and more large,the capacity of power system must be bigger and the grid be more intensive. And the environment of ship is so bad,water erosion is always there,the insulation fault of power system often happens,so how to monitor the insulation fault become important. This paper research the insulation monitoring technology,propose single frequency signal insulation monitoring way. At last,design online insulation monitoring system based on DSP.
作者 陈珊珊
出处 《舰船科学技术》 北大核心 2015年第1期165-168,共4页 Ship Science and Technology
关键词 绝缘监测系统 双频信号 DSP insulation monitoring system dual frequency signal DSP
  • 相关文献

参考文献8

  • 1SEPPO H ,MATTI L,ERKKI A. A method for detection and location of high resistance earth faults [ C ]//IEEE Catalogue No98EX137 ,1998 :495 - 500.
  • 2GAN Z, DONG X Z, BO Z Q, et al. A new protection scheme for high impedance fault using adaptive trip and reclosure technique [ C ]//IEEE, 2002 : 295 - 299.
  • 3叶华,程剑,李运成.基于CADDS5的舱室绝缘建模方法及其应用[J].舰船科学技术,2007,29(6):12-14. 被引量:4
  • 4BUTLER K L,SARMA N D R,WHITCOMB C A,et al. Shipboard systems deploy automated protection [ J ]. IEEE Computer Applications in Power, 1998,11 ( 2 ) :31 - 36.
  • 5AMIT S, BRIAN K J. Evaluation of grounding and protection methods for a shipboard power system. Electric Ship Technoogies Symposium [ C ]//IEEE ,2005 : 117 - 124.
  • 6王小锋,马俊,刘春林,韩灿峰.舰船通海系统管路腐蚀影响因素及控制方法浅析[J].舰船科学技术,2009,31(12):54-57. 被引量:22
  • 7ZERO Sequence Parameters Measurement for Ineffectively Earthed Power Systems, Transmission and Distribution Conference and Exhibition: Asia and Pacific [ C]//IEEE/ PES ,2005 : 1 - 5.
  • 8曾祥君,尹项根,陈德树,张哲.中性点非有效接地配电网故障选线新原理(英文)[J].Journal of Southeast University(English Edition),2000,16(1):64-69. 被引量:3