期刊文献+

医院容灾备份系统的研究与实施 被引量:9

The Research and Implementation of Disaster Recovery System
下载PDF
导出
摘要 随着医院信息化建设的不断深入,所产生的医疗数据量也越来越大,数据类型也越来越复杂,数据安全成为了现代医院信息系统安全的重中之重,如何构建一个统一、高效、安全可靠的存储管理体系,已成为当前医院信息化建设推进过程中亟须解决的重要问题。在对医疗数据存储研究的基础上,提出了基于虚拟化的容灾备份设计理念,通过采用虚拟化和块级数据同步引擎等先进技术,建立了无中断、零数据丢失的层次化容灾备份管理系统。通过建设虚拟化容灾备份系统,信息系统稳定性、可靠性得到了显著提升,实现了业务连续性保护。结论:基于虚拟化容灾备份系统的建设,最终实现了医疗数据的远程实时备份、信息系统的无中断运行及数据零丢失,保障了医院业务的正常开展。 Objective: With the further development of hospital information construction, the amount of medical data is more and more increasing,and type of the medical data is more and more complex. Data security has become a top priority for modern hospital information system. How to build auniform, efficient, safe and reliable storage management systembecomes a problem to be solved imperatively in the current improvement of hospital information construction. Methods: Based on the study of the medical data sto- rage, this paper puts forward the design concept of virtualization-baseddisaster recovery. By adoptingsuchadvanced technology as- virtualization, block-level data synchronization engine and so on, it establishes anuninterrupted, zero data lossand hierarchical disas- ter recoverymanagement system. Results: By establishing the disaster recoverymanagement system, the stability andreliability of hospitalinformation system is improved significantly and assures the continuity of hospitals' operation. Conclusion:The constructio- nor virtualization-based disaster recovery management systemrealizes the real-time distance backup of medical data, uninterruptedo- oeration of hospital information system and zero data loss. It guarantees the normal operation of the medical services.
机构地区 宝安人民医院
出处 《微型电脑应用》 2015年第2期17-18,30,共3页 Microcomputer Applications
基金 深圳市宝安区科技局课题(2013191)
关键词 虚拟化 数据存储 容灾备份 CACHÉ Virtualization Data Storage Disaster Recovery Cache
  • 相关文献

参考文献8

  • 1宝安区卫生局.深圳市宝安区卫生事业“十二五”发展规划[Z].2013.
  • 2深圳市宝安区.深劫I市宝安区人民政府关于加快卫生事业科学发展的实施意见[z].2013.
  • 3Chen P M, Lee E K, Gibson G A, et al. RAID: Highper- formance,Reliable Secondary Storage[J]. ACM Compu- tingSurveys, 1994, 26(2): 145-185.
  • 4Kochut A, BobroffN, Beaty K, et al. Management Issues inStorage Area Networks[C].//Proc. ofNOMS'04. Seoul, Korea:[s. n.], 2004: 453-466.
  • 5向小佳,余宏亮.一种基于存储虚拟化的异步远程镜像系统[J].计算机学报,2009,32(10):1905-1914. 被引量:5
  • 6JiMinwen, Alistair V, John W. Seneca: Remote Mirro- ringDone Write[C].//Proc. of USENIX'03. San Antonio, USA:[s. n.], 2003.
  • 7Michail F, Angelos B. Clotho: Transparent Data Version- ing atthe Block I/O Level[C].//Proc. of MSST'04. College Park,USA: IEEE Computer Society, 2004.
  • 8Xiao Weijun, Liu Yinan, Yang Qing, et al. Implementation andPerformance Evaluation of Two Snapshot Methods on iSCSITarget Stores[C].//Proc. of MSST'06. College Park, USA:IEEE Computer Society, 2006.

二级参考文献7

  • 1Veritas Volume Replicator Option by Symantec--A Guide to Understanding Volume Replicator, Engineering White Paper, Symantec, 2006.
  • 2Michail F, Angelos B. Clotho: Transparent data versioning at the block I/O level//Proceedings of the 21st IEEE Conference on Mass Storage Systems and Technologies (MSST 04). Greenbelt, Maryland, USA. IEEE Computer Society, 2004: 315-328.
  • 3Akshat V, Kaladhar V, Ramani R, Rohit J. SWEEPER: An efficient disaster recovery point identification mechanism// Proceedings of the USENIX File and Storage Technologies (FAST 08). San Jose, California, USA. USENIX Association, 2008:297-312.
  • 4EMC SRDF: Zero data loss solutions for extended distance replication. EMC Corporation: Technical Report P/N 300- 006-714, REV A03, 2009.
  • 5Hugo P, Stephen M, Mike F, Dave H, Steve K, Shane O. SnapMirror: File system based asynchronous mirroring for disaster recovery//Proceedings of the USENIX File and Storage Technologies (FAST 02). Monterey, California, USA. USENIX Association, 2002:117-129.
  • 6Hitz D, Lau D, Malcolm M. File system design for an NFS file server appliance//Proceedings of the 1994 Winter USENIX Technical Conference. San Francisco, California, USA. USENIX Association, 1994: 235-245.
  • 7Minwen J, Alistair V, John W. Seneca: Remote mirroring done write//Proceedings of the USENIX Annual Technical Conference (USENIX 03). San Antonio, Texas, USA. USENIX Association, 2003:253-268.

共引文献6

同被引文献63

引证文献9

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部