期刊文献+

心血管磁共振临床应用及进展 被引量:11

Progress and clinical application of cardiovascular magnetic resonance
下载PDF
导出
摘要 RSNA2014心血管磁共振(cardiovascular magnetic resonance imaging,CMR)热点如下:在缺血性心脏病的应用主要集中在评估微血管阻塞(microvascular obstruction,MVO)与急性心梗后左室重塑的关系及其预后价值;在心脏瓣膜疾病的应用主要集中在肺动脉瓣及三尖瓣病变右心室心态及功能的监测;先天性心脏病方面的研究采用了3D SPACE及4D PC(phase contrast)技术,取得较好的成果;心脏定量成像技术介绍了细胞外间质容积分数(extracellular volume fraction,ECV)在心肌病、糖尿病及重型地中海贫血中的应用价值。 The CMR in RSNA 2014 mainly focused on the following aspects: The correlation between microvascular obstruction (MVO) and left ventricular remodeling after acute myocardial infarction, and the prognostic value of MVO in ischemic cardiac disease; the assessment of right ventricular morphology and function in pulmonary valve and tricuspid diseases; the application of 3D SPACE and 4D phase contrast in congenital cardiac diseases; cardiac quantitative imaging described the value of ECV(extracellular volume fraction) in cardiomyopathy, diabetes and thalassemia major.
出处 《磁共振成像》 CAS CSCD 2015年第2期86-90,共5页 Chinese Journal of Magnetic Resonance Imaging
基金 国家自然科学基金重点项目(编号:81130029)
关键词 磁共振成像 缺血性心脏病 瓣膜病变 先天性心脏病 定量成像技术 Magnetic resonance imaging Ischemic cardiac disease Valvedisease Congenital heart disease Quantitative cardiac imaging
  • 相关文献

参考文献16

  • 1van Kranenburg M, Magro M, Thiele H, et al. Prognostic value of microvascular obstruction and infarct size, as measured by CMR in STEMI patients. JACC Cardiovascular imaging, 2014, 7(9): 930-939.
  • 2Kandler D, Lucke C, Grothoff M, et al. The relation between hypointense core, microvascular obstruction and intramyocardial haemorrhage in acute reperfused myocardial infarction assessed by cardiac magnetic resonance imaging. European radiology, 2014, 24(12): 3277-3288.
  • 3Pereira E, Bettencourt N, Ferreira N, et al. Incremental value of adenosine stress cardiac magnetic resonance in coronary artery disease detection. International journal of cardiology, 2013, 168(4): 4160- 4167.
  • 4Korosoglou G, Gitsioudis G, Voss A, et al. Strain-encoded cardiac magnetic resonance during high-dose dobutamine stress testing for the estimation of cardiac outcomes: comparison to clinical parameters and conventional wall motion readings. Journal of the American College of Cardiology, 2011, 58(11): 1140-1149.
  • 5Eicken A, Ewert P, Hager A, et al. Percutaneous pulmonary valve implantation: two-centre experience with more than 100 patients. European heart journal 2011, 32(10): 1260-1265.
  • 6Buddhe S, Shah A, Lai WW. Progression of right ventricular dilation in repaired tetralogy of Fallot. J Magn Reson Imaging, 2014 Mar 4. doi: 10.1002/jmri.24610.[Epub ahead of print].
  • 7尹刚,贺光军,赵世华.心血管MRI第三部分——心血管磁共振临床应用概述[J].磁共振成像,2013,4(6):450-458. 被引量:10
  • 8李国斌,张卫军.三维快速自旋回波成像技术——SPACE[J].磁共振成像,2010,1(4):295-298. 被引量:61
  • 9Stankovic Z, Allen BD, Garcia J, et al. 4D flow imaging with MR1. Cardiovascular diagnosis and therapy, 2014, 4(2): 173-192.
  • 10Lee JJ, Liu S, Nacif MS, et al. Myocardial TI and extracellular volume fraction mapping at 3 tesla. Journal of cardiovascular magnetic resonance: official journal of the Society for Cardiovascular Magnetic Resonance, 2011, 13: 75.

二级参考文献26

  • 1Mugler JP III, Kiefer B, Brookeman JR. Three-dimensional T2-weighted imaging of the brain using very long spin-echo trains In: Proceedings of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: ISMRM, 2000:1630.
  • 2Mugler JP Ⅲ, Meyer H, Kiefer B. Practical implementation of optimized tissue specific prescribed signal evolutions for improved turbo-Spin Echo imaging. In: Proceedings of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: ISMRM, 2003: 203.
  • 3Morita S, Ueno E, Masukawa A, et al. SPACE vs. 3D TSE MRCP at 1.5T MRI with Regard to Difference of Echo Spacing. In: Proceedings of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: ISMRM, 2009: 4018.
  • 4Park J, Mugler JP III, Horger W, et al. Optimized T1- weighted contrast for single-slab 3D turbo spin-echo imaging with long echo trains: Application to whole-brain imaging. Magn Reson Med, 2007, 58(5): 982-992.
  • 5Li GB, Sauerbier C, Paul D, et al. Verse-Space. In: Proceedings of the International Society for Magnetic Resonance in Medicine. Berkeley. Calif: ISMRM, 2010: 3036.
  • 6Mugler JP III, Brookeman JR. Efficient spatially-selective single-slab 3D turbo-spin-echo imaging. In: Proceedings of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif:ISMRM, 2004: 695.
  • 7Li GB, Paul D, Zhang WJ, et al. Multi-slab SPACE. In: Proceedings of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: ISMRM, 2010: 3037.
  • 8Li GB, Nittka M, Hollenbach HP, et al. The shifted radial reordering for intermediate TE imaging in 3D long echo train acquisition. In: Proceedings of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: ISMRM, 2009: 2623.
  • 9Priatna A, Foster G, Xu J, et al. NATIVE SPACE angiography with MTC and fat saturation pulses. In: Proceedings of file International Society for Magnetic Resonance in Medicine. Berkeley, Calif:ISMRM, 2009: 1878.
  • 10Xu J, Weale P, Gerhard L, et al. A novel non-contrast MR angiography technique using triggered non-selective refocused SPACE for improved spatial resolution and speed. In: Proceedings of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif:ISMRM, 2008:730.

共引文献69

同被引文献95

引证文献11

二级引证文献74

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部