低剂量CT心血管造影对成人先心病诊断的价值 被引量:2

The clinical utility of Low-Dose and wide range restrospective ECG-gated cardiac CTA in adults with congenital heart disease
下载PDF
导出
摘要 目的通过图像质量评价和诊断评价,探讨低剂量CT心脏大血管造影(CCTA)对成人先天性心脏病(CCHD)诊断的价值。方法 143位CCHD阳性患者和7位CCHD阴性患者采用MSCT进行低剂量CCTA检查。计算有效辐射剂量。对成像质量进行主、客观评价;以经胸超声(TTE)为对照,进行诊断评价。结果平均有效剂量为(5.95±0.28)mSv。图像信噪比(SNR)为11.31±2.92。CTA和TTE诊断心内畸形的准确度分别为90.4%,96.8%(P=0.152);诊断心外大血管连接畸形的准确度分别为94.1%,80.4%(P=0.022);诊断心外大血畸形的准确度分别为100%,68.7%(P=0.000)。结论低剂量心脏大血管造影的图像质量能够满足CCHD诊断的要求。 Objective To evaluate the feasibility and clinical utility of low-dose and wide range restrospective ECG-gated cardiac CTA in adults with congenital heart disease. Methods This prospective study included 150 adult patients who un- derwent low-dose and wide range restrospective ECG-gated cardiac CTA and transthoracic echocardiography (TTE). The effective radiation dose was calculated and the imaging quality was assessed by quantitative measurements and subjective e- valuation. The diagnostic accuracy was calculated and compared based on surgery, thoracoscopic surgery,cardiac interven- tional procedure and/or conventional cardiac angiography. Results The calculated effective radiation dose was (5. 95± 0.28) mSv. The attenuation of pulmonary artery was (243.18±48.25) HU (≥200 HU in 84% of patients). The attenu- ation of aortic artery was (263.93±71.51) HU (≥200HU in 89% of patients). The calculated SNR (signal to noise ratio) and CNR (contrast to noise ratio) of cardiac cavity were 11.31±2.92, 8.26±2.68 respectively. The imaging quality of cardiac cavity was subjectively evaluated as excellent in 80.7% of patients. The diagnosable rate of each segment of coronary arteries was greater than or equal to 81%. The diagnostic accuracy of cardiac CTA and TTE in intra cardiac anomalies was 90.4% and 96.8%0 ( P =0. 152) respectively and in cardiac-arterial connection anomalies was 94.1% and 80.4% ( P = 0. 022) respectively and in extra cardiac anomalies was 100 % and 68.7 % ( P 〈 0. 000) respectively. Conclusion Wide range retrospective ECG--gated cardiac CTA can be performed using a low-dose protocol. The image quality has the ability to meet the requirements of morphological diagnosis in adult patients with congenital heart disease. Compared with TTE, the Cardiac CTA has unique advantages.
出处 《医学影像学杂志》 2015年第1期55-59,共5页 Journal of Medical Imaging
关键词 先天性心脏病 体层摄影术 X线计算机 血管造影 低剂量 Cardiac computed tomography angiography Radiation dose Congenital heart disease X-ray computed
  • 相关文献

参考文献8

  • 1Broberg C, Meadows AK. Advances in imaging: the impact on the care of the adult with congenital heart disease [J]. Prog Cardiovasc Dis, 2011, 53(4) : 293-304.
  • 2Babar JL, Jones RG, Hudsmith L, et al. Application of MR imaging in assessment and follow-up of congenital heart dis ease in adults [J]. Radiographics, 2010, 30(4): 1145.
  • 3Bongartz G, Golding SJ, Jurik AG, et al. European guide lines on quality criteria for computed tomography [J]. Publi cation EUR 16262 EN. www. drs. dk/guidelines/ct/quality/ mainindex, htm. Accessed October 28, 2008.
  • 4Raff GL. Radiation dose from coronary CT angiography: five years of progress [J]. J Cardiovasc Comput Tomogr, 2010, 4 (6) : 365-374.
  • 5Thompson RC, Cullom SJ. Issues regarding radiation dosage of cardiac nuclear and radiography procedures [J].J Nucl Car diol, 2006, 13(1) : 19-23.
  • 6Van Praagh R. Diagnosis of complex congenital heart disease: morphoiogic-anatomic method and terminology [J]. Cardio- vasc Intervent Radiol, 1984, 7(3-4) : 115-120.
  • 7Lapierre C, Dery J, Guerin R, et al. Segmental approach to imaging of congenital heart disease [J]. Radiographics, 2010, 30(2): 397-411.
  • 8张丽红,李勇,赵艳玲.前置门控冠状动脉CTCA低剂量成像技术的应用价值[J].医学影像学杂志,2014,24(7):1152-1155. 被引量:1

二级参考文献10

  • 1郑吉锋.医疗仪器设备维修管理工作探讨[J].医疗卫生装备,2005,26(9):35-36. 被引量:35
  • 2郭萍,漆家学,谭永福,母小东.浅谈基层医院医疗设备管理的现状及对策[J].医疗卫生装备,2005,26(9):38-38. 被引量:14
  • 3Andreini D, Pontone G, Mushtaq S, et al. A long term prognostic value of coronary CT angiography in suspected coronary artery disease[J]. J Am Coll Cardiol Imaging, 2012, 5: 690-701.
  • 4Brenner DJ. Hall EJ. Computed tomography an increasing source of radiation exposure [J]. N Engl J Med. 2007. 7157: 2277-2284.
  • 5Hong C, Becker CR, Huber A. et al. ECG gated recon structed multi-detector row CT coronary angiography: effec of varying trigger delay on image quality [J]. Radiology 2011, 220(3):712-717.
  • 6Flohr TG, Schoepf UJ, Kuettner A. et al. Advances in card iac imaging with 16- section CT systems [J]. A cad Radiol 2013,10: 3861.
  • 7Feucbtner GM, Jodocy D, Klauser A, et al. Radiation dose reduction by using 100 kV tube voltage in cardiac 64 slice computed tomography: a comparative study[J]. Eur J Radiol, 2011, 75(1): 51 56.
  • 8Hausleite RJ, Meyer T, Hadamitzky M, et al. Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on efectivedose estimates [J]. Circulation, 2006, 113: 1305.
  • 9王妍焱,吴国庚,周诚,高建华,焦晟,曹会志.64层螺旋CT前门控冠状动脉横断面扫描低剂量技术的初步研究[J].中华放射学杂志,2008,42(10):1018-1021. 被引量:79
  • 10蒋海洪,梁学林,奚健.对在用医疗器械实施风险管理的思考[J].中国医疗器械杂志,2012,36(2):128-132. 被引量:29

同被引文献12

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部