期刊文献+

Effectiveness and Safety of Double-balloon Catheter versus Intra-amniotic Injection of Ethacridine Lactate for Termination of Second Trimester Pregnancy in Patients with Liver Dysfunction 被引量:14

Effectiveness and Safety of Double-balloon Catheter versus Intra-amniotic Injection of Ethacridine Lactate for Termination of Second Trimester Pregnancy in Patients with Liver Dysfunction
下载PDF
导出
摘要 Severe liver dysfunction in pregnancy(SLDP) is rare but serious complications with high mortality rate. This study compared the effectiveness and safety of double-balloon catheter versus intra-amniotic injection of ethacridine lactate for the termination of second trimester pregnancy in patients with SLD. A total of 55 patients with indications of labor induction were enrolled and analyzed by retrospective control analysis method. Twenty-three cases adopted Cook double balloon dilation as Cook group, and 32 cases received intra-amniotic injection of ethacridine lactate as EL group. The primary outcome was evaluated by successful abortion rate and the difference in the induction-to-abortion interval. Secondary outcomes included liver function recovery and the frequency of adverse events. Both Cook and EL regimens were effective, with successful abortion rate of 87.0% and 93.8%, respectively(P=0.639). The induction-to-delivery interval was similar between Cook group and EL group(38.1±21.5 vs. 41.3±17.4, P=0.543). The liver disease status was more severe in Cook group than in EL group, but it did not show any significant difference after pregnancy termination between the two groups and the improvement rate also did not show any significant difference. Both treatments were safe and there was no significant difference in bleeding and cervical laceration adverse events between the two groups. Our study firstly compared double-balloon catheter and ethacridine lactate for the induction of labor in women with SLD during second trimester pregnancy. Severe liver dysfunction in pregnancy(SLDP) is rare but serious complications with high mortality rate. This study compared the effectiveness and safety of double-balloon catheter versus intra-amniotic injection of ethacridine lactate for the termination of second trimester pregnancy in patients with SLD. A total of 55 patients with indications of labor induction were enrolled and analyzed by retrospective control analysis method. Twenty-three cases adopted Cook double balloon dilation as Cook group, and 32 cases received intra-amniotic injection of ethacridine lactate as EL group. The primary outcome was evaluated by successful abortion rate and the difference in the induction-to-abortion interval. Secondary outcomes included liver function recovery and the frequency of adverse events. Both Cook and EL regimens were effective, with successful abortion rate of 87.0% and 93.8%, respectively(P=0.639). The induction-to-delivery interval was similar between Cook group and EL group(38.1±21.5 vs. 41.3±17.4, P=0.543). The liver disease status was more severe in Cook group than in EL group, but it did not show any significant difference after pregnancy termination between the two groups and the improvement rate also did not show any significant difference. Both treatments were safe and there was no significant difference in bleeding and cervical laceration adverse events between the two groups. Our study firstly compared double-balloon catheter and ethacridine lactate for the induction of labor in women with SLD during second trimester pregnancy.
出处 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2015年第1期129-134,共6页 华中科技大学学报(医学英德文版)
基金 supported by a grant from the National Natural Science Foundation of China(No.81372806)
关键词 severe liver dysfunction labor induction double-balloon catheter mechanical method ethacridine lactate severe liver dysfunction labor induction double-balloon catheter mechanical method ethacridine lactate
  • 相关文献

参考文献1

二级参考文献1

共引文献10

同被引文献102

引证文献14

二级引证文献114

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部