一种提高超声波多普勒流量计测量精度的方法 被引量:4

Method for Improving Doppler Flow Meter Measurement Accuracy
下载PDF
导出
摘要 由于强噪声背景下的多普勒超声波回波信号属于微弱信号,传统谱分析方法对微小多普勒偏移量的测量误差较大,使得现有的超声多普勒流量计在应用范围和测量精度上受到限制,因此提出采用Zoom FFT结合卡尔曼滤波来提高多普勒流量计的测量精度。文中首先采用Zoom FFT来提高多普勒回波信号的频率分辨率,然后通过卡尔曼滤波器递推跟踪频率偏移值,最后在Matlab环境下实现了Zoom FFT算法和卡尔曼滤波算法。现场测试结果表明:采用Zoom FFT结合卡尔曼滤波可以提高流量测量精度。 As the Doppler ultrasonic echo signal under strong noise background is belongs to the weak signal, the measure- ment error is large when the traditional spectrum analysis method was used to extract the doppler offset quality, so the usage of Doppler flow meter is limit in the application field and measurement accuracy for velocity doppler flow meter, A new method using Zoom FFT and kalman filter was adopted to improve the Doppler flow meter measurement accuracy. This paper used Zoom FFT to improve the frequency Doppler echo signal resolution, and then tracked the frequency offset value. The Zoom FFT algorithm and kalman algorithm under the Matlab environment were realized. The field test result shows that the flow measurement accuracy can be improved using Zoom FFF and kalman filter.
出处 《仪表技术与传感器》 CSCD 北大核心 2015年第2期33-35,共3页 Instrument Technique and Sensor
基金 陕西省教育厅实验室基金(12JS078) 陕西省科技统筹创新工程计划项目(2012KTCL01-10)
关键词 超声波流量计 测量精度 ZOOM FFT 卡尔曼滤波器 MATLAB ultrasonic flow-meter measurement accuracy Zoom FFT kalman filter measurement accuracy Matlab
  • 相关文献

参考文献9

二级参考文献67

  • 1王照峰,王仕成,苏德伦.锁相环电路的基本概念及应用研究[J].电气应用,2005,24(8). 被引量:46
  • 2丁杨斌,申功勋.Unscented粒子滤波在静基座捷联惯导系统大方位失准角初始对准中的应用研究[J].航空学报,2007,28(2):397-401. 被引量:16
  • 3Stimson G W.机载雷达导论[M].2版.北京:电子工业出版社,2005.
  • 4JULIER S J, UHLMANN J K. Unscented filtering and nonlinear estimation [ J ]. Proceeding of the IEEE ,2004,92 (3) :401-402.
  • 5樊红娟.无先导卡尔曼滤波算法分析[D].重庆:西南大学,2007.
  • 6Wang Yuhui. New-type ultrasonic flow meter design based on FPGA high-speed data sampling[ C]//The 9th International Conference on Electronic Measurement & Instruments. Beijing, China, 2009:509 - 512.
  • 7Li Mingwei, Lu Guosheng, Hu Yanguo. Research on improving the accuracy of the ultrasonic flow-meter with time difference method [ C ]//IEEE International Conference on Electrical and Control Engineering. Wu- han, China, 2010 : 1704 - 1707.
  • 8Inoue Y, Kikura H, Murakawa H, et al. A study of ul- trasonic propagation for ultrasonic flow rate measure- ment [ J ]. Flow Measurement and Instrumentation, 2008, 19 (34) :223 - 232.
  • 9Pavlovic V, Dimitrijevic B, Stojcev M, et al. Realiza-tion of the ultrasonic liquid flowmeter based on the pulse-phase method [J]. Ultrasonics, 1997, 35( 1 ) :87 - 102.
  • 10Takamoto M, Ishikawa H, Shimizu K, et al. New measurement method for very low liquid flow rates using ultrasound [ J ]. Flow Measurement and Instru- mentation, 2001, 12(4): 267-273.

共引文献76

同被引文献34

引证文献4

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部