期刊文献+

飞秒激光在角膜屈光手术应用中的并发症 被引量:12

Complications of femtosecond laser in corneal refractive surgery
下载PDF
导出
摘要 飞秒激光是一种以脉冲发射的低能量红外线激光,具有切削精确、安全性高、重复性好等特点,可用于角膜屈光手术中制作角膜瓣、角膜基质内切割、制作角膜切口等。尽管飞秒激光的应用使得角膜屈光手术更加安全,但仍然存在一些不容忽视的并发症,本文就飞秒激光在角膜屈光手术中的并发症作一综述。 Femtosecond laser is a pulsed infrared laser emitting low energy with cutting precision, safety and high reproducibility. It can make corneal flap, cut the cor- neal stroma and corneal incision and so on in corneal refractive surgery. Although the application of femtosecond laser enables corneal refractive surgery safer, some compli- cations can not be ignored. This article reviews the complications of femtosecond laser in corneal refractive surgery.
作者 李仲佶 李雪
出处 《眼科新进展》 CAS 北大核心 2015年第2期197-200,共4页 Recent Advances in Ophthalmology
基金 黑龙江省哈尔滨市科技创新人才研究专项基金(编号:2010RFLXS010) 黑龙江省教育厅科学技术专项基金(编号:12521263) 黑龙江省人事厅留学回国人员科技项目择优资助基金(编号:2012-134)~~
关键词 飞秒激光 角膜屈光手术 并发症 femtosecond laser corneal refractive surgery complication
  • 相关文献

参考文献27

  • 1Srinivasan S, Herzig S. Sub-epithelial gas breakthrough during femtosecond laser flap creation for LASIK [J]. Br J Ophthal- mol,2007,91 (10) : 1373-1375.
  • 2田廷原,赵小虎,马海鹰.2438眼飞秒激光制作角膜瓣并发症的临床观察[J].川北医学院学报,2011,26(3):241-242. 被引量:6
  • 3Munoz G,Albarran-Diego C, Sakla HF, Javaloy J,Alio JL. Transi- ent light-sensitivity syndrome after laser in situ keratomileusis with the femtosecond laser incidence and prevention[ J]. J Cat- araet Refract Surg,2005,32 ( 12 ) :2075-2079.
  • 4Payman H, Sonia H, George Y, Kymioni S, Takeshi I. Complica- tions of LASIK flaps made by the intralase 15-and 30-kHz femto- second lasers[J].J Refract Surg ,2009,25 ( 5 ) :979-984.
  • 5de Paula FH, Khairallah CG, Niziol LM. Diffuse lamellar keratitis after laser in situ keratomileusis with femtosecond laser flap creation[J]. J Cataract Refract 8urg,2012,38( 6 ) :1014-1019.
  • 6Gil-Cazorla R, Teus MA, de Benito-Llopis L, Fuentes I. Incidence of diffuse lamellar keratitis after laser in situ keratomileusis as- sociated with the intralase 15 kHz femtosecond laser and Moria M2 microkeratome[J]. J Cataract Refract Surg, 2008,34 ( 1 ) : 28 -31.
  • 7Ide T, Kymionis GD, Goldman DA, Yoo SH, O' Brien TP. Sub- conjunctival gas bubble formation during LASIK flap creation u- sing femtoseeond laser [J]. J Refract Surg, 2008,24 ( 8 ) : 850- 851.
  • 8Rocha KM, Kagan R, Smith SD, Krueger RR. Thresholds for in- terface haze formation after thin-flap femtosecond laser in situ keratomileusis for myopia[J].Am J Ophthalmol,2009,147 ( 6 ) : 966-972.
  • 9Kymionis GD, Portaliou DM, Krasia MS. Unintended epithelium- only flap creation using a femtosecond laser during LASIK[J]. J Refract Surg ,2011,27 ( 1 ) :74-76.
  • 10Dougherty P J, Wellish KL, Maloney RK. Excimer laser ablation rate and corneal hydration [J]. Am J Ophthalmol, 1994, 118 (2) :169-176.

二级参考文献15

  • 1姜涛,黄振平,薛春燕,杨丽萍.准分子激光原位角膜磨镶术后与瓣相关并发症及处理[J].医学研究生学报,2005,18(7):626-628. 被引量:5
  • 2黄振平.屈光手术的最新技术及其临床应用[J].医学研究生学报,2007,20(4):337-338. 被引量:22
  • 3sugar A. Ultra-fast ( femtosecond ) laser reflractive surgery [ J ]. Curropin Ophthalmol,2002,13:246 -249.
  • 4Stern D, Lin WZ, Puliafito CA, Fujimoto JG-Femtoseeond optical ranging of corneal incision depth. Investigative Ophthalmology Visual Science. 1989 ;Jan;30( 1 ) :99 - 104.
  • 5Binder PS. Flap dimensions created with the IntraLase FS laser. J Cataract Refract Surg. 2004 ;Jan ;30 ( 1 ) :26 - 32.
  • 6Holzer MP,Rabsilber TM,Auffarth GU. Femtoseeond laser-assisted corneal flap cuts : morphology, accuracy, and histopathology. Invest Ophthalmol Vis Sci. 2006 ;Jul ;47 (7) :2828 - 31.
  • 7Tran DB, Sarayba MA, Bor Z, Garufis C, Duh YJ, Soltes CR, Juhasz T, Kurtz RM. Randomized prospective clinical study comparing induced aberrations with lntraLase and Hansatome flap creation in fellow eyes: potential impact on wavefront - guided laser in situ keratomileusis. J Cataract Refract Surg,2005 ;Jan;31 ( 1 ) : 97 - 105.
  • 8Soong HK, Malta JB. Femtosecond lasers in ophthalmology [ J ]. Am J Ophthalmol, 2009, 147(2) : 189-197.
  • 9Faktorovich EG. Femtodynamics: optimizing femtosecond laser set- tings and procedure techniques to optimize outcomes [ J ]. Int Oph- thalmol Clin, 2008, 48 (1) : 41-50.
  • 10Tran DB, Binder PS, Brame CL. LASIK flap revision using the IntraLase femtosecond laser [ J ].Int Ophthalmol Clin, 2008, 48 (1) : 51-63.

共引文献13

同被引文献111

  • 1牟章兵,杜之渝.有晶状体眼人工晶状体植入术研究进展[J].眼科新进展,2005,25(1):90-92. 被引量:3
  • 2王勤美.屈光手术学[M].2版.北京:人民卫生出版社,2011.
  • 3Faktororich E G.Femtodynamics:optimizing femtosecond laser settings and procedure techniques to optimize outcomes[J].Int Opthalmol Clin,2008,48(1):41-50.
  • 4Norrby S.Sources of error in intraocular lens power calculation[J].J Cataract Refract Surg,2008,34(3):368-376.
  • 5Mehdizadeh M.Effect of axial length and keratometry measurement error on intraocular lens implant power prediction formulas in pediatric patients[J].J AAPOS,2008,12(4):425-426.
  • 6Wang Q,Savini G,Hoffer K J,et al.A comprehensive assessment of the precision and agreement of anterior corneal power measurements obtained using 8 different devices[J].PLo S One,2012,7(9):e45607.
  • 7Manning C A,Kloess P M.Comparison of portable automated keratometry and manual keratometry for IOL calculation[J].J Cataract Refract Surg,1997,23(8):1213-1216.
  • 8Lanza M,Iaccarino S,Cennamo M,et al.New Scheimpflug camera device in measuring corneal power changes after myopic laser refractive surgery[J].Cont Lens Anterior Eye,2015,38(2):115-119.
  • 9Masoud M,Livny E,Bahar I.Repeatability and intrasession reproducibility obtained by the Sirius anterior segment analysis system[J].Eye Contact Lens,2015,41(2):107-110.
  • 10Savini G,Barboni P,Carbonelli M,et al.Accuracy of corneal power measurements by a new Scheimpflug camera combined with Placido-disk corneal topography for intraocular lens power calculation in unoperated eyes[J].J Cataract Refract Surg,2012,38(5):787-792.

引证文献12

二级引证文献60

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部