摘要 隔离型直流变换器通常应用于直接将电网电能进行变换或有特殊要求的场合,根据变压器铁心在磁化曲线上工作区域的不同,可以分成单端和双端变换器。通过对双端变换器直流偏磁问题的研究,利用TMS320F28335芯片ePWM模块的工作原理,介绍了一种新型的死区定时器控制方法,最后用该方法对双端推挽式电路进行实验,证明此方法用于抑制偏磁产生的可行性。 Isolated DC-DC converter is usually applied directly to the grid power transformation or specialrequirement,according to the different work area of the hysteresis loop of the transformer core,it can be divided intosingle-ended and double-ended converter.Through the study of the double-ended converter bias-magnetic problem,taking advantage of the working principle of e PWM module of chip TMS320F28335,a new dead- time controltechnique was presented. Finally,the experiment of controlling a double-ended circuit demonstrates the accuracy ofthis method.
出处 《电气传动》 北大核心 2015年第2期13-15,共3页 Electric Drive
关键词 直流偏磁 双端变换器 ePWM模块 DC bias double-ended converter ePWM module
  • 相关文献

参考文献4

二级参考文献6

  • 1Noriaki suginohara, Akinori Fujimoto, Hamhito Kubota, et al. Countermeasure against DC Excitation of 220 kV Transformer [R]. IEEJ Nagoya 2001,1924-1925.
  • 2N Takasu, T Oshi, F Miyawaki, et al. An experimental analysis of DC excitation of transformers by geomagnetically induced currents [J].IEEE Transactions on Power Delivery, 1994,9(2).
  • 3John G Kappenman .Effects of geomagnetic disturbances on power systems [A ]. Panel Session of PES Summer Meeting [C ].California:1989.
  • 4P Picher, L Bolduc, A Dutil, et al. Study of the acceptable DC current limit in core - form power transformers [ J ]. IEEE Transactions on Power Delivery, 1997, 12 ( 1 ).
  • 5江苏省电力科学研究院.三峡直流输电对江苏电网设备的影响研究技术报告[R].,2003..
  • 6杨正龙,王慧贞.一种新型推挽正激变换器[J].电力电子技术,2002,36(1):36-39. 被引量:16