摘要 目的探讨不同包装对灭菌口腔小器械在生物安全柜中的有效期的影响。方法在生物安全柜中,对高压灭菌后玻璃器皿包装和纸塑包装的口腔小器械在不同时间点进行细菌采样培养实验,在第1天打开玻璃器皿包装的灭菌小器械后的4、8、24 h进行采样,以后每间隔24小时采集1次,连续10 d采样观察其细菌生长情况,同时在每一个时间点均采集一次纸塑包装的灭菌器械作为实验对照。结果在生物安全柜相对无污染的情况下,对照组均无细菌生长,实验组在144 h的培养结果开始有菌落生长,168 h后的培养结果有统计学意义(P<0.05)。结论在生物安全柜中相对无污染的条件下,玻璃器皿包装的口腔诊疗中的小器械的有效期远远超过《医疗机构口腔诊疗器械消毒技术操作规范》所规定的包装灭菌物品一经打开不得超过4 h的标准。 Objective To explore the validity period of oral sterilizing instruments in different packages inside the bio-safety cabinet. Methods Inside the bio-safety cabinet, we brought the autoclaved dental gadgets packed in glassware and paper-plastic into microbial sampling cultivation experiment, and made observation of the bacteria growth at the 4th, 8th, 24th hour after sterilizing, with the sampling of once per 24 hours, lasting 10 days. Samples taken from the gadgets in paper-plastic each time when samples were taken from the gadgets in glassware were as the control. Results Under the condition that the bio-safety cabinet was not contaminated, no colony grew in neither group in 144 hours; 168 hours later, the cultivation results indicated that colonies started to grow (P 〈 0.05). Conclusion Under the condition that the bio-safety cabinet is pollution-free, the validity period of gadgets in glassware packaging for dental clinic practices is far longer than the 4-hour limit after the sterilized packages are opened, as is stipulated in the "Operating Specifications for Sterilization Technology on Dental Instruments of Medical Institutions".
出处 《华西医学》 CAS 2015年第2期233-235,共3页 West China Medical Journal
基金 泸州市科技局课题[2013-S-50(2/3)]~~
关键词 高压灭菌 有效期 纸塑包装 玻璃器皿包装 Autoclaving Validity period Paper-plastic packaging Glassware packaging
  • 相关文献

参考文献13

  • 1邹咏梅,汪鸿文,汪志强,潘溢泓,丁小竹,谢任远.杭州市口腔诊疗机构消毒灭菌现状[J].中国感染控制杂志,2009,8(3):192-194. 被引量:4
  • 2王颖.口腔专科医院小器械的消毒灭菌[J].中国消毒学杂志,2008,25(2):220-221. 被引量:3
  • 3中华人民共和国卫生部.医疗机构口腔诊疗器械消毒技术操作规范[EB/OL].(2005-03-03)[2013-05-10].http://www.jkb.corn.cn/htmlpage/2/26197.htm?docid=26197&-cat=nulllsKeyWord=null.
  • 4Raju TB, Garapati S, Agrawal R, et al. Sterilizing Endodontic Files by four different sterilization methods to prevent cross-infection: an In-vitro study[J]. J Int Oral Health, 2013, 5(6): 108-112.
  • 5Brusca MI, Mosca CO, Nastri N, et al. Long-term sterility of orthodontic-surgical appliances[J]. J Dent Res, 2003, 82(C): 10.
  • 6张素芹,王琳,韩春云.纸塑袋包装物品高压灭菌后有效期分析[J].临床医学,2010,30(10):123-124. 被引量:4
  • 7中华人民共和国卫生部.WS/T367-2012医疗机构消毒技术规范[S].2012.
  • 8中华人民共和国卫生部.WS/T368-2012医院空气净化管理规范[S].北京:中华人民共和国卫生部,2012.
  • 9余树荣. 微生物学和微生物学检验[M]. 北京: 人民卫生出版社, 1997: 439-449.
  • 10王春燕.口腔科诊疗器械消毒灭菌存在的问题及对策[J].中华医院感染学杂志,2010,20(1):67-68. 被引量:21

二级参考文献18

共引文献47

同被引文献56

引证文献4

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部