期刊文献+

PAR指数评价蛙式矫治器治疗安氏Ⅱ类错的矫治效果 被引量:2

Assesement the outcome of Frog appliance in treating angle 2 malocclusion using Peer assessment rating (PAR) index analysis
下载PDF
导出
摘要 目的:运用PAR指数评价蛙式矫治器远移上颌磨牙治疗安氏Ⅱ类错的矫治效果。方法:选取蛙式矫治器治疗的安氏Ⅱ类错病例20例,运用PAR指数对每一病例矫治前后的石膏模型进行测量评价,对实验结果用SPSS13.0软件进行统计分析。结果:20例病例PAR总分值矫治前后分别17.72±3.48,2.28±1.63减少15.44±2.76,差异有极显著性(P<0.01);加权PAR总分矫治前后27.25±5.68,3.70±2.58,减少23.55±3.97,差异有显著性(P<0.01);PAR总分值加权前后减少百分率分别为89.61%,86.42%。结论:通过PAR指数的评价认为蛙式矫治器通过远移上颌磨牙可以有效治疗部分安氏Ⅱ类错。 Objective:To evaluate the occlusal outcome of Frog appliance in distal movement of maxillary molars by PAR index.Methods:20classⅡmalocclusion cases treated with Frog were chosen.PAR index was used in assessing every patient's dental cast before and after orthodontic therapy,and SPSS13.0software package was used for paired-sampled test.Results:The PAR Score of 20 patients was 17.72±3.48 before treatment and was 2.28±1.63 after treatment,which decrcased significantly(P〈0.01).The weight PAR Score was 27.25±5.68 before treatment and was 3.70±2.58 after treatment.The mean reduction of PAR Score was 15.44±2.76,with the percentage reduction was 89.61%.And the mean reduction of weight PAR Score was 23.55±3.97 with the percentage reduction was 86.42%.Conclusion:Peer assessment rating(PAR)index analysis indicated some kinds of classⅡ malocclusion can be treated effectively by Frog appliance.
出处 《陕西医学杂志》 CAS 2015年第2期207-209,共3页 Shaanxi Medical Journal
关键词 错(牙合) 安氏Ⅱ类 正畸学 矫正 @PAR指数 @蛙式矫治器 Malocclusion angle class Ⅱ Orthodontics corrective @Frog appliance @PAR index
  • 相关文献

参考文献7

  • 1Birkeland K,Furevik J,Boe OE,et al.Evaluationof treatment and post-treatment changes by the PAR index[J].Eur J Orthod,1997,19(3):279.
  • 2司新芹,张彩娣,李湘琳,卢蓁.Frog磨牙远移器和Cetlin推磨牙方法的临床对比研究[J].陕西医学杂志,2014,43(6):683-685. 被引量:6
  • 3Richmond S,Shaw WC,O′Brien KD,et al.The development of the PAR index(peer assessment rating):Reliability and validity[J].Eur J Orthod,1992,14(2):125-139.
  • 4DeGuzman L,Bahiraei D,Vig KW,et al.The validation of the peer assessment rating index for malocclusion severity and treatment difficulty[J].Am J Orthod Dentofacial Orthop,1995,107(2):172-176.
  • 5Richmond S,Shaw WC,Roberts CT,et al.The PAR index(peer assessment rating):Methods to determine outcome of orthodontic treatment in terms of improvement and standards[J].Eur J Orthod,1992,14(3):180-187.
  • 6Buchana IB,ShawWC,Richmond S,et al.A comparison of the reliability and validity of the PAR Index and Summers’Occlusal Index[J].Eur J Orthod,1993,15(1):2.
  • 7司新芹,李湘琳,张彩娣,卢蓁.Frog磨牙远移器的临床应用研究[J].中国美容医学,2013,22(16):1708-1713. 被引量:4

二级参考文献11

  • 1Keim,Robert G.Solving the molar-distalization dilemma[J].J Clin Orthod,2012,46(8):453-454.
  • 2Nur Metin,Bayram Mehmet,Celikoglu Mevlut.Effects of maxillary molar distalization with Zygoma-Gear Appliance[J].Angle Orthod,2012,82(4):596-602.
  • 3Catalfamo Lorenza,Gasperoni Enrico,Celli Daniel.Class Ⅱ treatment with the smart distalization technique[J].J Clini Orthod,JCO,2012,46(10):613-624.
  • 4Gokhan O,Ozlem S,Banu D.Osseointegrated implants with pendulum springs for maxillary molar distalization:A cephalometric study[J].Am J Orthod Dentofacial Orthop,2007,131:16-26.
  • 5Antonarakis GS,Kiliaridis S.Maxillary molar distalization with noncompliance intramaxillary appliances in Class II malocclusion.A systematic review[J].Angle Orthod,2008,78(6):1133-1140.
  • 6Nur M,Bayram M,Celikoglu M.Effects of maxillary molar distalization with Zygoma-Gear Appliance[J].Angle Orthodontist,2012,82(4):596-602.
  • 7Catalfamo L,Gasperoni E,Celli D.Class II treatment with the smart distalization technique[J].JCO,2012,46(10):613-624.
  • 8Cetlin NM,Ten-Hoeve A.Nonextraction treatment[J].J Clin Orthod,1983,17:396-413.
  • 9Ghosh J,Nanda RS.Evaluation of an intraoral maxillary molar distalization technique[J].Am J Orthod,1996,110:639-646.
  • 10李文星,李强,刘晶.改良蛙式矫治器的研制与初步临床应用[J].中华口腔正畸学杂志,2011,18(1):6-10. 被引量:2

共引文献7

同被引文献22

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部