摘要 为提高海上平台高压配电间安全性,减少SF6气体泄漏引发的人身伤害,分析JZ20-2中北平台配电间SF6高压断路器的使用现状及安全性,特别是SF6断路器泄漏气体特性及对人员危害性,指出平台现有SF6断路器配电间所存在的安全隐患,提出安全性改进意见,引进SF6气体在线监测系统,实现对配电间内SF6气体在线监测,保证平台人员人身安全。 The status and safety of SF6 circuit breakers on the JZ20-2 platforms are analyzed, especially with the character- istics and its damage of gas leakage of SF6 circuit breaker. The hidden dangers of SF6 circuit breaker in MCC are pointed out. The safety improvements are proposed for the existing situation and Introduced the concept of online monitoring of SF6 circuit breakers. The gas leakage of SF6 circuit breaker can greatly improve the safety factor in MCC and also reduced the personal injury.
出处 《船海工程》 2014年第5期41-43,47,共4页 Ship & Ocean Engineering
关键词 SF6断路器 高压配电盘 气体泄漏检测 SF6 circuit breakers distributor gas leak detection
  • 相关文献

参考文献2

  • 1罗学深.SF6气体绝缘全封闭组合电器(GIS〉[M].北京:中国电力出版社,1998.
  • 2苑舜.高压开关设备状态监测与诊断技术[M].北京,机械工业出版社,2000.