期刊文献+

比值-导数光谱法测定APMP制浆废水的色度 被引量:1

Chroma Determination of APMP Pulping Wastewater by Ratio-derivative Spectrometry
下载PDF
导出
摘要 基于比值-导数光谱的基本原理提出了一种测定碱性过氧化氢机械浆(APMP)制浆废水色度的新方法,检测结果不受pH值和废水中悬浮物的影响,255 nm可作为比值-导数光谱测定色度的检测波长,当待测样品的色度值范围在50~1 130度之间时,准确值与预测值之间的相关系数为0.996 4,相对偏差在±8%之内。与传统色度检测方法相比,新方法操作简便,降低了人为因素造成的误差,且无需消耗化学试剂,可以满足APMP制浆废水色度的测定要求。 A new method is described to measure the chroma of APMP pulping effluent by using ratio-derivative spectrometry.Adjusting the pH value and removing suspended substance before detection of chroma were not necessary in this method,and the detection wavelength was 255 nm. Precision and accuracy were suitable,and relative deviation was within ± 8 % when the chroma of samples was in the range of 50- 1 130 C. U. In contrast to the traditional methods,the present test procedure was simplified and the error caused by human factors was minimized. No other chemicals were applied during the whole test procedure and the method was an environmental friendly approach for chroma determination. Ratio-derivative spectrometry was satisfactory for the chroma determination of APMP pulping effluent.
出处 《林产化学与工业》 EI CAS CSCD 北大核心 2014年第5期35-40,共6页 Chemistry and Industry of Forest Products
基金 国家自然科学基金资助项目(31070525 31270627) 高等学校科技计划项目(05032501)
关键词 制浆废水 比值-导数光谱 色度 高得率浆 pulping effluent ratio-derivative spectrometry chroma high yield pulp
  • 相关文献

参考文献13

  • 1汪大鼍,徐新华,宋爽,等.工业废水中专项污染物处理手册[M].北京:化学工业出版社,2000.
  • 2国家环保局《水和废水监测分析方法》编委会.水和废水监测分析方法[M].3版.北京:中国环境科学出版社,1989.
  • 3HACH Company. HACH DR/2010 Spectrophotometer[ M ]. USA : HACH Company, 1996-2000.
  • 4Method NCASI 253. U. S. Environmental Protection Agency. Analytical Methods for the Determination of Pollutants in Pulp and Paper Industry Wastewater[ M1. Washington DC :Office of Water Engineering and Analysis Division, 1993 : 125-142.
  • 5NORGAARD L, RIDDER C. Spectmphotometric determination of mixtures of 2-,3-,and 4-hydroxybenzaldehydes by flow injection analysis and uv/vis photodiode -array detection [ J ]. Talanta, 1994,41 ( 1 ) : 59 -66.
  • 6PALABIYIK I M, DIN.C E, ONUR E. Simultaneous spectrophotometric determination of pseudoephedrine hydrochloride and ibuprofen in a pharmaceutical preparation using ratio spectra derivative speetrophotometry and multivariate calibration techniques [ J ]. Journal of Pharmaceutical and Biomedical Analysis ,2004,34 ( 3 ) :473-483.
  • 7ERK N. Comparative study of the ratio spectra derivative speetrophotometry,derivative spectrophotometry and Vierordt' s method applied to the analysis of lisinopril and hydrochlorothiazide in tablets[ J ]. Spectroscopy Letters, 1998,31 (3) :633-645.
  • 8KARIMI S, ABDULKHANI A,GHAZALI A H B, et al. Color remediation of chemimechanical pulping effluent using combination of enzymatic treatment and Fenton reaction [ J 1. Desalination,2009,249 (2) :870-877.
  • 9STEPHENSON R J, DUFF S J B. Coagulation and precipitation of a mechanical pulping effluent-I : Removal of carbon, colour and turbidity [ J ]. Water Research, 1996,30 (4) :781-792.
  • 10KLENIN V I,SHCHEGOLE~ S Y. Principles of optimization of turbidimetric titration of polymer solutions[ J ]. Polymer Science USSR, 1979, 21 (9) :2373-2384.