摘要
对泉州市移动通信GSM基站和TD-SCDMA基站电磁辐射状况进行监测与分析。通过理论计算预测基站电磁辐射安全距离,对典型敏感目标、典型基站进行电磁辐射的监测,结果与理论预测情况相符。选取302个GSM基站和306个TD-SCDMA基站进行电磁辐射的监测,结果表明,各基站电磁辐射满足单个项目管理低于目标限值0.08 W/m2的标准。分析表明,基站在正常运行时,对周围的电磁辐射环境影响能满足国家相应标准的要求。
The electromagnetic radiation of mobile communication base stations of Quanzhou city, including GSM and TD-SCDMA were monitored and analyzed. The safety distance of electromagnetic radiation of mobile communication base station was theoretically calculated. The monitoring results of typical sensitive target and typ- ical base station were in accordance with the theoretical prediction results. 302 GSM base stations and 306 TD- SCDMA base stations were selected for the electromagnetic radiation monitoring. The results showed that the base station electromagnetic radiation meets to the individual project's limit 0.08 W/m2. Analysis showed that the e- lectromagnetic radiation of a normally running base station can meet the requirements of national standard.
出处
《环境监测管理与技术》
2014年第5期56-60,共5页
The Administration and Technique of Environmental Monitoring
关键词
移动通信基站
电磁辐射
环境影响
泉州市
Mobile communication base stations
Electromagnetic radiation
Environmental influence
Quanzhou