期刊文献+

均布荷载作用下保温龙骨足尺墙体的抗弯性能 被引量:10

Bending behaviour of full-scale walls with light-gauge slotted steel studs subjected to distributed loading
下载PDF
导出
摘要 为研究腹板开孔的轻钢龙骨墙体在均布荷载作用下的抗弯性能,考虑腹板高度的影响,进行3.0 m×3.0 m足尺试件试验研究.分析了不同腹板高度的墙体在均布荷载作用下的破坏模式及腹板高度对墙体抗弯性能的影响.在此基础上,采用ABAQUS建立墙体的有限元模型,与试验结果进行对比分析,验证了有限元模型的可靠性.分析结果表明:石膏板可很好地限制竖龙骨的整体屈曲,当龙骨腹板高度为150 mm时,墙体竖龙骨在支座附近发生腹板剪切屈曲,同时在跨中位置发生畸变与局部屈曲的相关屈曲破坏;当龙骨腹板高度为100 mm时,墙体竖龙骨在跨中位置发生畸变与局部屈曲的相关屈曲破坏;当不考虑窗洞口影响时,腹板高度为100 mm的保温龙骨外围护墙体可满足我国全部地区建筑高度不超过50 m的城市建筑外围护墙体的抗风要求. Full-scale experiments were carried out to investigate the static responses of light-gauge slotted steel stud walls with different web heights subjected to uniformly distributed transverse loading. The failure modes for the walls were depicted. The influence of the web height on the static behaviour of this new kind of light-gauge steel stud walls was analyzed. By means of ABAQUS,finite element model was built to numerically investigate the bending behaviour of the full-scale light-gauge slotted steel stud walls. The analysis results were benchmarked against the experimental ones. It was concluded that the gypsum board can prevent the studs from overall buckling.The stud wall with web height of 150 mm failed in shear mode at the support and buckled in both the local and distortional mode at the mid span,while the stud wall with web height of 100 mm only failed with local and distortional buckling at the mid span. When there is no window hole,the slotted steel stud wall with a web height of 100 mm can resist the wind loading in China for the building with the height lower than 50 m.
出处 《哈尔滨工业大学学报》 EI CAS CSCD 北大核心 2014年第8期16-20,共5页 Journal of Harbin Institute of Technology
基金 哈尔滨市科技创新人才研究专项资金项目(2012RFLXG025)
关键词 腹板开孔轻钢龙骨 抗弯 足尺 试验研究 ABAQUS light-gauge slotted steel studs bending resistance full scale experimental investigation ABAQUS
  • 相关文献

参考文献12

  • 1IFE L W. The performance on cold-formed steel products in housing [ C]//Proceedings of the 3rd International Conference on Cold-Formed Steel Design and Construction. Louis : Missouri, 1975 : 621-667.
  • 2TH(YR) T. Strength of slotted steel studs [ D ]. Sweden : Royal Institute of Technology, 2001.
  • 3HOGLUND T, BURSTRAND H. Slotted steel studs to reduce thermal bridges in insulated walls [ J ]. Thin- Walled Structures, 1998, 32(1/2/3) :81-109.
  • 4KESTI J, MKELINEN P. Design of gypsum-sheathed perforated steel wall studs [ J ]. Journal of Constructional Steel Research, 1998, 46(1/2/3) : 215-216.
  • 5SALHAB B, WANG Y C. A study of the thermal performance of cold-formed thin-walled perforated steelstuds ( Thermal Studs ) in fire [ C ]//Proceedings of the Ninth Biennial ASCE Aerospace Division International Conference on Engineering, Construction, and Operations in Challenging Environments. Houston : [s.n.] , 2004: 688-695.
  • 6SALMI P. Design of web-perforated steel wall studs [ C ]//4th Finnish Steel Structures R&D Days. Lappeenranta, Finland : [ s.n. ] , 1998.
  • 7FREDERIKSEN J O, SPANGE H. Danogips stalbyggesystem [ R ]. Denmark: Underscgelseaf bzereevnen af lette ydervagge, Byggeteknisk Institut, 1992.
  • 8BORGLUND J,JONSSON J. BarfOrmaga fir slitsade stalreglar [ D ]. Denmark : Examensarbete 84, Institutionen fr Byggkonstruktion, 1997.
  • 9石敬斌,董晓晨,杨晓杰,耿悦,孙建运.腹板开孔轻钢龙骨在均布荷载作用下的抗弯性能有限元分析[J].建筑钢结构进展,2013,15(4):1-7. 被引量:10
  • 10颜於腾.腹板开孔轻钢龙骨围护墙体保温性能研究[D].哈尔滨:哈尔滨工业大学土木工程学院,2012.

二级参考文献18

  • 1周绪红,石宇,周天华,刘永健,周期石,狄谨,卢林枫.低层冷弯薄壁型钢结构住宅体系[J].建筑科学与工程学报,2005,22(2):1-14. 被引量:134
  • 2洪强.钢结构住宅的优势及综合效益分析[J].安徽建筑,2006,13(4):110-112. 被引量:7
  • 3颜於腾.腹板开孔轻钢龙骨围护墙体保温性能研究[D].哈尔滨:哈尔滨工业大学土木工程学院,2012.
  • 4THOYR~ T. Strength of slotted steel studs [ D ]. Sweden: Royal Institute of Technology, Department of Structural Engi- neering, 2001.
  • 5IFE L W. The performance on cold-formed steel products in housing[ C]//Proceedings of the 3rd International Conference on Cold-Formed Steel Design and Construction. Missouri St. Louis, SUA: S&T(formerly the University of Missuuri-Rolla), 1975 : 621-667.
  • 6ENGEBRETSEN P A, RAMSTAD T D. Vegger med stMprofiler av tynnplater[ R]. Arbeidsrapport 15, Norges Byggforskn- ings Institutt, Dimensjonering av bserevegger, Norwegian, 1978.
  • 7FREDERIKSEN J O, SPANGE H. Danogips stMbygge system [ R ]. Underscgelseaf bsereevnen af lette yderv- ~egge. Technical Report 13726, Byggeteknisk Institut. Danish, 1992.
  • 8SALMI P. Design of web-perforated steel wall studs[ C]//Proceedings of the gth Finnish Steel Structures. Lappeenranta, Finland : R&D days, 1998.
  • 9HOGLUND T, BURSTRAND H. Slotted steel studs to reduce thermal bridges in insulated walls [ J ]. Thin-Walled Struc- tures, 1998, 32(1-3) :81-109.
  • 10沐敬木.腹板开孔的轻钢龙骨围护墙体足尺试验研究[D].哈尔滨:哈尔滨工业大学土木工程学院,2012.

共引文献14

同被引文献98

引证文献10

二级引证文献38