基于呼吸音的呼吸监测方法初探 被引量:6

Primary Study of Respiratory Monitoring Based on Breath Sounds
下载PDF
导出
摘要 由于呼吸音与呼吸气流速度之间存在着非线性关系,因此呼吸音有可能成为新的呼吸监测方法。该文首先提取了呼吸音的振幅包络信号,并证明了包络信号对数与呼吸气流速度之间良好的线性相关性,之后通过回归分析获取不同受试者的线性模型参数,并利用模型参数实现了基于包络信号对数的呼吸气流速度模拟,误差可控制在14.9%以下。因此,使用呼吸音对呼吸气流速度进行模拟并实现基于呼吸音的呼吸监测是可行的。 It is nonlinear relationship between breath sounds and respiratory flow rate, thus breath sounds might be a new solution for respiratory monitoring. The envelope of the breath sounds was created firstly. And the linear relationship between the logarithm of envelope and the respiratory flow rate was proved. Then model parameters were derived from every subject using regression analysis. Finally, using these parameters estimated respiratory flow rate was achieved by the logarithm of envelope with 14.9% error. Therefore, respiratory flow rate estimation and respiration monitoring based on breath sounds are feasible.
出处 《中国医疗器械杂志》 CAS 2015年第1期21-24,共4页 Chinese Journal of Medical Instrumentation
关键词 呼吸音 包络 呼吸气流模拟 breath sounds envelope respiratory flow rate estimation
  • 相关文献

参考文献10

  • 1Lira S. Metabolic acidosis[J]. Acta Med Indones, 2007, 39(3): 145- 150.
  • 2Miller RD, Eriksson LI, Fleisher LA, et al. Miller's anesthesia[M]. Philadelphia: Churchill Livingstone, 2009:2971-2997.
  • 3Cretikos MA, Bellomo R, Hillman K, et al. Respiratory rate: the neglected vital sign[J]. Med J Aust, 2008, 188( 11): 657-659.
  • 4王镭,刘春生,张芮恺,陈熹,李志坚,李振宇,叶继伦,张旭.呼吸功能检测方法研究[J].中国医疗器械杂志,2012,36(5):338-341. 被引量:4
  • 5Ahmed IS, Aziz E, Newton N. Connection of capnography sampling tube to an intravenous cannula[J]. Anaesthesia, 2005, 60(8): 824-825.
  • 6Keidan I, Gravenstein D, Berkenstadt H, et al. Supplemental oxygen compromises the use of pulse oximetry for detection of apnea and hypoventilation during sedation in simulated pediatric patients[J]. Pediatrics, 2008, 122(2): 293-298.
  • 7Gottfridsson C, Daum D, Kennergren C, et al. Acute evaluation of transthoracic impedance vectors using ICD leads[J]. Pacing Clin Electrophysiol, 2009, 32(6): 762-771.
  • 8Folke M, Cernerud L, Ekstrom M, et al. Critical review of non- invasive respiratory monitoring in medical care[J]. Med Biol Eng Comput, 2003, 41(4): 377-383.
  • 9Gavriely N, Cugell DW. Airflow effects on amplitude and spectral content of normal breath sounds[J]. J Appl Physiol (1985), 1996, 80(1): 5-13.
  • 10于璐,张勇德,沙宪政.Labview和Matlab混合编程方法在生物医学信号分析中的应用[J].中国医疗器械杂志,2011,35(1):15-18. 被引量:7

二级参考文献13

共引文献9

同被引文献59

  • 1郑静,凌莉,张福林,杨才布.门诊病人满意度的测量和评价[J].中华医院管理杂志,2004,20(6):372-374. 被引量:70
  • 2朴商.阻塞性睡眠呼吸暂停综合征的发病因素[J].国外医学(呼吸系统分册),1994,14(2):81-82. 被引量:28
  • 3郭劲松,邓亲恺.可穿戴式心电、呼吸传感器与检测系统的研制[J].中国医疗器械杂志,2006,30(5):341-344. 被引量:23
  • 4KATZ J D.Noise in the operating room[J].Anesthesiology,2014,121:894-898.
  • 5ALLAOUCHICHE B,DUFLO F,DEBON R,et al.Noise in the postanaesthesia care unit[J].B J Anaesth,2002,88(3):369-373.
  • 6FRITSCH M H,CHACKO C E,PATTERSON E B.Operating room sound level hazards for patients and physicians[J].Otology&Neurotology,2010,31(5):715-721.
  • 7ZAEN J V,MURRAY M M,MEULI R A,et al.Adaptive filtering methods for identifying cross-frequency couplings in human EEG[J].Plos one,2013,8(4):e60 513.
  • 8SUVI T,MIKKO T,TAPIO S.Reducing the effect of respiration in baroreflex sensitivity estimation with adaptive filtering[J].IEEE Trans Biomed Eng,2008,55(1):51-59.
  • 9LAURITA D S,JOAQUIM J B,EIBERT E N M,et al.Application of an automatic adaptive filter for Heart Rate Variability analysis[J].Medical Engineering&Physics,2013,35:1 778-1 785.
  • 10柴敬安,廖克俭,潘德辉,李淼.Labview和Matlab混合编程方法的研究与实现[J].计算机测量与控制,2008,16(5):737-739. 被引量:42

引证文献6

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部