超长眼轴白内障患者手术前后眼生物测量参数变化 被引量:5

The variation in biometric parameters of cataract patients with over-long axial length before and after operation
原文传递
导出
摘要 目的分析超长眼轴白内障患者超声乳化手术前后眼生物测量参数变化。方法分析2013年9月至2014年2月在我院行晶状体超声乳化吸出联合IOL植入手术的超长眼轴白内障15例(20只眼)。分别应用光学相干生物测量法(IOLMaster)及超声生物显微镜法(UBM)测出手术前及术后3个月眼生物测量参数,以SPSS17.0统计软件对数据进行分析。结果术后3个月与术前相比,眼轴长度缩小,差异有统计学意义;前房深度增加,差异有统计学意义;角膜曲率元改变。手术年龄与术前眼轴长度呈负相关关系,年龄与术前角膜曲率、术前前房深度无相关关系。术前眼轴长度、术前角膜曲率、术前前房深度三者之间,彼此均无相互关系。术后前房深度与术前眼轴长度、术前角膜曲率、术前前房深度无相互关系。结论超长眼轴白内障术后眼轴变短,前房加深,术后前房深度预测仍需进一步研究。 Objective To analyze the change of biometric parameters for patients with over-long axial length after cataract surgery. Methods Twenty eyes of 15 patients, from September 2013 to Feburary 2014 in Xuanwu Hospital were recruited for this study. Phacoemulsification and IOL implantation were performed in those cataract patients. The ocular biometric parameters were recorded by optical coherence biometry ( IOL Master) and ultrasound biomieroscopy (UBM) before surgery and three months after surgery. Statistical software package SPSS 17.0 was used to analyze statistically. Results Compared with the preoperative hiometrie parameters, the axial length shortened and the anterior chamber deepened after surgery, and the difference was statistically significant. The corneal curvature had no significant difference three months after the surgery. There was negative relationship between age and preoperative axial length. No correlation was found between age and preoperative corneal curvature or preoperative anterior chamber depth. Preoperative axial length, preoperative corneal curvature, and preoperative anterior chamber depth had no correlation between each other. There was no correlation between postoperative anterior chamber depth and preoperative axial length, or preoperative corneal curvature, or preoperative anterior chamber depth. Conclusion For cataracts with over-long axial length, the axial length shortened and the anterior chamber depth deepened after cataract surgery. The prediction of postoperative anterior chamber depth still needs to study further.
出处 《中华眼外伤职业眼病杂志》 2015年第2期95-98,共4页 Chinese Journal of Ocular Trauma and Occupational Eye Disease
基金 基金项目:首都医科大学基础-临床科研合作基金重点课题资助项目(1000172404)
关键词 白内障 晶状体 人工 超长眼轴 生物测量 Cataract Lens, intraocular Axial, over-long Biometry
  • 相关文献

参考文献15

二级参考文献85

  • 1鲁宇容,石浔,郭海科.超声乳化人工晶状体植入术治疗高度近视白内障[J].眼科新进展,2004,24(6):472-474. 被引量:7
  • 2李刚,张方华,颜少明,彭秀军.标准化logMAR视力表的研制与临床应用[J].第二军医大学学报,2005,26(12):1371-1373. 被引量:19
  • 3姜燕,施玉英,杨文利.六种人工晶状体屈光度数计算公式的准确性比较[J].眼科,2007,16(2):100-103. 被引量:12
  • 4Tsiklis NS, Kymionis GD, Karp CL, et al. Nine-year follow-up of a posterior chamber phakie IOL in one eye and LASIK in the fellow eye of the same patient[J]. J Refract Surg, 2007, 23(9) :935 -937.
  • 5Morrison D, Sternberg P, Donahue S. Anterior chamber intraocular lens (ACIOL) placement afler pars plana lensectomy in pediatric Marfan syndrome[J]. J AAPOS, 2005, 9(3) :240 -242.
  • 6Kwong YY, Yuen HK, Larn RF, et al. Comparison of outcomes of primary scleral-fixated versus primary anterior chamber intraocular lens implantation in complicated cataract surgeries. Ophthalmology [J]. 2007, 114(1): 80-85.
  • 7Chan CK, Hawkins H, Lin SG.. Modified haptic externalizing technique for repositioning dislocated 1-piece acrylic posterior chamber implants [J].Can J Ophthalmol. 2007, 42(4) :573 -579.
  • 8Wallace DK, Pllager DA. Corneal diameter in childhood aphakic glaucoma[ J ]. J Pediatr Ophthalmol Strabisumus, 1996, 33 (5) :230 - 234.
  • 9Allemann N, Chamon W, Tanaka HM, et al. Myopic angle-supported intraocular lenses; two-year follow-up[J]. Ophthalmology, 2000 (8), 107 : 1549 - 1554.
  • 10Rufer F, Schroder A, Erb C. White-to-white corneal diameter: normal values in healthy humans obtained with the Orbscan II topography system[J]. Cornea, 2005, 24(3): 259-261.

共引文献88

同被引文献50

  • 1汤萍,张惠颖,王红.人工晶状体植入术后前房深度的变化分析[J].中华眼科杂志,2006,42(1):32-36. 被引量:24
  • 2张舒,袁鹂,李苏梅.白内障超声乳化术中前房深浅对角膜曲率的影响[J].临床眼科杂志,2006,14(5):418-420. 被引量:3
  • 3Findl 0,Drexler W, Menapace R, et al. Improved prediction Of in-traocular lens power using partial coherence interferometry.Cataract Refract Surg, 2001, 27(6):861-867.
  • 4Olsen T. Sources of error in intraocular lens power calculation. JCataract Refract Surg, 1992,18(2): 125-129.
  • 5Polizzi A,Schenone M, Ciurlo C, et al. Echobiometric evaluation ofthe axial length of the eye and intraocular lens calculation in pseu-dophakic eyes: our experience. Ophthalmologia, 1998, 212(Suppl 1):25-26.
  • 6Olsen T, Thorwest M. Calibration of axial length measurements withthe Zeiss IOLMaster. J Cataract Refract Surg, 2005,31 (7):1345-1350.
  • 7Atchison DA, Smith G. Possible errors in determining axial lengthchanges during accommodation with the IOLMaster. Optom Vis Sci,2004, 81(4): 283-286.
  • 8Donald R, David A. The vision myopic implantable collamer lensdoes not significantly affect axial length measurement with the IOL-Master. J Refract Surg, 2008, 24(5):957-959.
  • 9Lesiewska-Junk H, Malukiewicz-Winiewska G. Axial length mea-surements after cataract surgery in adults. Ophthalmologica, 2(K)2,216(4): 239-241.
  • 10Terzi E,Wang L, Kohnen T. Accuracy of modem intraocular lenspower calculation formulas in refractive lens exchange for highmyopia and high hyperopia. J Cataract Refract Surg, 2009, 35(7):1181-1189.

引证文献5

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部