期刊文献+

心血管介入虚拟手术造影剂显影仿真 被引量:2

Virtual Surgery Contrast Development Simulation with Cardiovascular Intervention
下载PDF
导出
摘要 心血管介入手术造影剂的使用对肾功能尤其对肾功能不全患者影响较大。在使用心血管介入手术模拟器进行手术培训过程中,造影剂剂量信号的检测是造影剂模拟的关键技术之一。将光学位移传感器用于造影剂注射剂量信号检测,并成功应用于心血管介入手术模拟器。通过Windows API提取光学位移传感器位移信息,并进行实验验证基于光学位移传感器的造影剂注射剂量信号检测的可行性。 The contrast agent used in cardiovascular interventional operation has advene effects on renal function,especially for the renal inadequacy patients.In the use of cardiovascular interventional operation simulator for operation training,detection of contrast agent signal has become one of the key techniques of contrast agent simulation.This paper presents the signal detection of contrast agent dose by using optical displacement sensor,and the successful application to cardiovascular interventional operation simulator.The installation box of sensor is manufactured by using 3D printing technology,the displacement information of optical displacement sensor is extracted by windows API,and experiments are conducted to verify the feasibility of contrast agent signal detection based on optical displacement sensor.
出处 《中国数字医学》 2015年第2期29-31,共3页 China Digital Medicine
基金 国家自然科学基金重大项目课题(编号:61190124 61190120) 国家自然科学基金国际合作项目(编号:61311140171) 国家高新技术研究发展计划(863)项目(编号:2006AA01Z310) 国家科技支撑计划重点项目课题(编号:2009BAI71B06) 上海市科委项目(编号:14441900800 14DZ1941100 14DZ1941102) 上海交通大学"医工(理)交叉研究基金"重点项目(编号:YJ2013ZD03 YG2012MS54) 上海市残疾人辅助器具资源中心科研项目~~
关键词 造影剂 光学位移传感器 心血管介入虚拟手术 contrast agent optical displacement sensor cardiovascular interventional virtual operation
  • 相关文献

参考文献2

二级参考文献9

  • 1Gupta R, Bimbaum Y, Uretsky BF. The renal patient with coronary artery disease. Current concepts and dilemmas [ J ]. J Am Coil Cardiol, 2004, 44 (7): 1343-1353.
  • 2Thomsen HS. Guidelines for contrast media from the European Society of Urogenital Radiology [J]. AIR Am J Roentgenol, 2003, 181 (6): 1463 - 1471.
  • 3Toprak O, Cirit M, Yesil M, et al. Impact of diabetic and pro - diabetic state on development of contrast - induced nephropathy in patients with chronic kidney disease [J]. Nephrol Dial Transplant, 2007, 22 (3) : 819 -826.
  • 4Jujo K, Yamaguehi J, Obayashi K, et al. Clinical impact of nephropathy induced by contrast medium in patients with acute myocardial infarction undergoing emergent coronary angiography [J]. J Cardiol, 2006, 48 (1): 9-16.
  • 5KATHOLI R E, TAYLOR G J, MCCANN W P, et al. Nephrotoxicity from contrast media: attenuation with theophyline [J]. Radiology, 1995, 195:17-22.
  • 6HEYMAN S N, REICHMAN J, BREZIS M. Pathophysiology of radicocontrast nephropathay: a role for medullary hypoxia[J]. Invest Radiol, 1999, 34:685-691.
  • 7WEISBERG L S, KURNIK P B, KURNIK B R. Radiocontrast-induced nephropathy in human: role of renal vasoconstriction [J]. Kidney Int, 1992, 41: 1408-1415.
  • 8DUAN SB, WU H W, LUOJ A, et al. Assessment of renal function in early stages of nephrotoxicity Inducd by iodinated contrastmedia [J]. Nephron,1999, 83:122-125.
  • 9陈庆海,府伟灵.尿微量蛋白检测及临床应用的研究进展[J].国外医学(临床生物化学与检验学分册),2002,23(3):178-180. 被引量:91

共引文献29

同被引文献3

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部