长石质和氟磷灰石饰瓷在模拟咀嚼循环条件下耐磨性能的研究 被引量:4

Abrasive resistance of feldspathic porcelain and fluorapatite porcelain under simulated oral environment
下载PDF
导出
摘要 目的:比较模拟咀嚼循环条件下长石质饰瓷与氟磷灰石饰瓷的耐磨性能。方法:制备2种饰瓷长条形试件各10个,用于物理性能测试和表面形貌观察;另制备圆盘形试件各6个,分别在水环境、加载力10 N、转速200 r/min的条件下进行120万次循环磨损实验;于每10万次循环节点测量各饰瓷的体积磨损量和表面粗糙度;然后分别在磨损10、70、120万次循环节点观察各饰瓷磨损面的微观形貌,分析磨损区域的基本组成及其所占比例。结果:两种饰瓷的体积磨损量、表面粗糙度曲线均呈现正相关近似线性上升趋势,在每个测量节点,氟磷灰石瓷的体积磨损量、表面粗糙度均明显高于长石质瓷(P<0.05);长石质瓷表面均匀一致,而氟磷灰石瓷表面有较多大小不一且散在分布的气孔;随着加载循环的进行,两种饰瓷的磨痕均由稀疏变为密集,磨损面上均可见磨屑粘着。结论:在模拟咀嚼循环条件下,氟磷灰石瓷的耐磨性能较长石质瓷差。 AIM: To compare the wear resistance of feldspathic porcelain( FEP) and fluorapatite porcelain( FLP) in simulated oral environment. METHODS: 10 rectangular samples of each group were subjected to wear test by means of three point bending method and the indentation method,the surface structure was observed by SEM after acid corrosion. 6 disc shaped samples in each group were subjected to wear test by a wear machine under water lubrication condition at the speed of 200 r / min and loading force of 10 N. The wear volume and roughness were measured by the three-dimensional profiler scanner per 105 cycles. Surface morphology were observed by SEM after 10^5,7 × 10^5,and 12 × 10^5 cycles respectively. EDX energy analysis was used to measure the basic composition and the proportion of the wear area. RESULTS: The volume loss,surface roughness of the two porcelains increased linearly with the wear process. The volume loss and surface roughness of FLP were higher than that of FEP at each measurement cycle. SEM images showed that there were many different sizes of pores on FLP surface. With the cyclic loading,the wear scar of the two materials became from sparse to dense. FLP was worn in the form of relatively small particles and relatively dense grooves. FEP was worn in the form of relatively big particles and relatively sparse grooves. There were visible particles adhered to the wear area. CONCLUSION: The wear resistance of fluorapatite porcelain is lower than that of feldspathic porcelain.
出处 《牙体牙髓牙周病学杂志》 CAS 2015年第2期84-89,124,共7页 Chinese Journal of Conservative Dentistry
基金 国家自然科学基金资助项目(81371176)
关键词 齿科陶瓷 磨损 三维形貌扫描 扫描电镜检查 dental ceramic wear 3D profiling scanning electron microscopy
  • 相关文献

参考文献20

  • 1Zakereyya SM. Albashaireh, BDS, MSc,Two-body wear of dif- ferent ceramic materials opposed to zirconia ceramic [ J 1. J Prosthet Dent, 2010, 104(2) :105 -113.
  • 2Preis V, Behr M, Kolbeck C, et al. Wear performance of sub- structure ceramics and veneering porcelains [ J ]. Dental Materi- als, 2011,27(8) :796 -804.
  • 3Park JH, Park S, Lee K, et al. Antagonist wear of three CAD/ CAM anatomic contour zirconia ceramics [ J]. J Prosthet Dent, 2014,111(1) :20 -29.
  • 4Kim M, Oh S, Kim J, et al. Wear evaluation of the human en- amel opposing different Y-TZP dental ceramics and other porce- lains[ J]. J Dent, 2012,40( 11 ) :979 -988.
  • 5Jung Y, Lee J, Choi Y, et al. A study on the in vitro wear of the natural tooth structure by opposing zironia or dental porcelain [J]. JAdv Prosthodont, 2010,2(3) :111.
  • 6Amer R, Kurklu D, Kateeb E, et al. Three-body wear potential of dental yttrium-stabilized zirconia ceramic after grinding, pol- ishing, and glazing treatments[ J]. J Prosthet Dent, 2014.
  • 7Wassell RW, Mccabe JF, Walls AW. Wear rates of regular and tempered composites [ J ]. J Dent, 1997,25 ( 1 ) :49 - 52.
  • 8姚月玲,马军萍,宋应亮,曹鸿涛,刘波,王晓波.不同牙用非贵金属材料与牙釉质间磨耗性能的测试研究[J].中国美容医学,2002,11(2):134-136. 被引量:10
  • 9Schindler I43, Stengel E, Spiess WE. Feedback control during mastication of solid food textures-a clinical-experimental study [ J]. J Prosthet Dent, 1998,80(3) :330 - 336.
  • 10Heintze SD. How to qualify and validate wear simulation devices and methods [ J]. Dent Mater, 2006,22 (8) :712 - 734.

二级参考文献14

  • 1戴松林.牙科合金研究述略[J].贵金属,1994,15(4):50-56. 被引量:5
  • 2Hudson JD.Enamel wear caused by three difierent restorative materials[J].J Prosthet Dent,1995,74:647-654.
  • 3Jacobi R,Shillingburg HT,Duncanson MG.A comparison of the abrasiveness of six ceramics and gold[J].J Prosthet Dent,1991,66:303-309.
  • 4Harrison A.Wear of combinations of acrylic resin and porcelain,on an abrasion testing machine[J].J Oral Rehabil,1978,5(2):111-115.
  • 5Knoblocb LA,Kerby RE,Seghi R.Two-body wear resistance and degree of conversion of laboratory-processed composite materials[J].Int J Prosthodont,1999,12(5):432-438.
  • 6Wassell RW,McCabe JF,Walls AWG.Wear rates of regular and tempered composites[J].J Dent,1997,25:49-52.
  • 7Graf K,Johnson GH,Mehl A,et al.The influence of dental alloys on three body wear of human enamel and dentin in an inlay-like situation[J].Oper Dent,2002,27(2):167-174.
  • 8Hacker CH,Wagner WC,Razoog ME.An in vitro investigation of the wear of enamel on porcelain and gold in saliva[J].J Prosthet Dent,1996,75:14-17.
  • 9Metzler KT,Woody RD,Miller AW,et al.In vitro investigation of the wear of human enamel by dental porcelain[J].J Prosthet Dent.1999,81:356-364.
  • 10Kelly JR,Nisbimura I,Campbell SD.Ceramics in dentistry:historical roots and current perspectives[J].J Prosthet Dent,1996,7(5):18-32.