氯工程BiTAC888电解槽膜极距改造和整体换膜后的效果评价及后期改善思路

Effect evaluation of membrane-thickness electrode-distance transformation of BiTAC888 electrolyzers and replacement of membrane and future improvement ideas
下载PDF
导出
摘要 对氯工程自然循环电解槽膜极距改造及整体换膜后,单元槽电压下降约240 m V,电耗下降约265k W·h/t,电流效率提高2.3%。介绍改造后的操作变化,对装置后期的稳定运行提出改善思路。 Natural-circulation electrolyzers made by Chlorine Engineers Company were transformed into membrane-thickness electrode distance ones and all of membrane were replaced. Unit cell voltage dropped by about 240 mV, power consumption decreased by about 265 kW · h/t, and current efficiency increased by 2.3%. Changes in post-transformation running were introduced. Improvement ideas of stable running of the electrolyzers in future were proposed.
出处 《氯碱工业》 CAS 2015年第2期8-10,共3页 Chlor-Alkali Industry
关键词 电解槽 膜极距 离子交换膜 效果评价 eleetrolyzer membrane-thickness electrode-distance ion-exchange membrane effectevaluation