期刊文献+

Ar(12+)Induced Irradiation Damage in Bulk Metallic Glass(Cu47Zr45Al8)98.5Y1.5

Ar(12+)Induced Irradiation Damage in Bulk Metallic Glass(Cu47Zr45Al8)98.5Y1.5
下载PDF
导出
摘要 The highly charged ion Ar^12+ with an energy of 3 Me V is used for irradiating metallic glass (Cu47Zr45Al8)98.5Y1.5 and polycrystalline metallic W at the irradiation fluences of 1× 10^14 ions/cm2, 1 × 10^15 ions/cm^2 and 1 × 10^16 ions/cm^2. The main structure of metallic glass remains an amorphous phase under different irradiation fluences according to x-ray diffraction analysis. The scanning electron microscope observation on the morphologies indicates that no significant irradiation damage occurs on the surface and cross section of the metallic glass sample after different fluences of irradiation, while a large area of irregular cracks and holes were observed on the surface of metallic W at a fluence of 1 ×10^16 ions/cm^2, with cracks and channel impairments at a certain depth from the surface. The root-mean-square (rms) roughness of metallic glass increases with increasing fluence of Ar^12+, while the reflectance decreases with increasing irradiation fluence. A nano-hardness test shows that the hardness of metallic glass decreases after irradiation. Under certain a higher capability of resistance to Ar^12+ irradiation in conditions, metallic glass (Cu47 Zr45Al8 )98.5 Y1.5 exhibits comparison with polycrystalline W. The highly charged ion Ar^12+ with an energy of 3 Me V is used for irradiating metallic glass (Cu47Zr45Al8)98.5Y1.5 and polycrystalline metallic W at the irradiation fluences of 1× 10^14 ions/cm2, 1 × 10^15 ions/cm^2 and 1 × 10^16 ions/cm^2. The main structure of metallic glass remains an amorphous phase under different irradiation fluences according to x-ray diffraction analysis. The scanning electron microscope observation on the morphologies indicates that no significant irradiation damage occurs on the surface and cross section of the metallic glass sample after different fluences of irradiation, while a large area of irregular cracks and holes were observed on the surface of metallic W at a fluence of 1 ×10^16 ions/cm^2, with cracks and channel impairments at a certain depth from the surface. The root-mean-square (rms) roughness of metallic glass increases with increasing fluence of Ar^12+, while the reflectance decreases with increasing irradiation fluence. A nano-hardness test shows that the hardness of metallic glass decreases after irradiation. Under certain a higher capability of resistance to Ar^12+ irradiation in conditions, metallic glass (Cu47 Zr45Al8 )98.5 Y1.5 exhibits comparison with polycrystalline W.
出处 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第2期110-114,共5页 中国物理快报(英文版)
基金 Supported by the National Natural Science Foundation of China under Grant Nos 11079012 and 11375037 the National Basic Research Program of China under Grant No 2010CB832901
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部