摘要 在台架试验中发现装备了C供应商的热力膨胀阀的定排量汽车空调系统在一些特定工况下会出现过热度异常现象,而更换成A供应商的热力膨胀阀该现象消失。然后,对C供应商和作者分别提出的热力膨胀阀不同参数更改方案进行相同的台架验证,证实本文所提方案对消除该现象有效。最后,整车级的环境模拟风洞试验显示,本文所提方案使该型汽车空调系统过热度异常现象消失且制冷性能有所改善。 The superheat of Fixed Automotive AC System with supplier C TXV is found unusual under some specified conditions during the bench test. But this phenomenon is disappeared if supplier A TXV is adopted. Then,different parameter change scheme of TXV was presented by supplier C and Author respectively. The same bench test was conduct,and authors' scheme is validated that can eliminate the unusual phenomenon. Finally,vehicle level test was conduct in climate wind tunnel,and the test data shows that the unusual superheat of this Fixed Automotive AC System has been disappeared and AC cooling performance has a little improvement.
出处 《流体机械》 CSCD 北大核心 2015年第2期80-84,28,共6页 Fluid Machinery
关键词 热力膨胀阀 过热度 汽车 空调 试验 TXV superheat automotive AC test
  • 相关文献

参考文献8

二级参考文献52

  • 1陈焕新,周云琦,杨培志.铁路客车空调系统几个现存问题的探讨[J].铁路技术创新,2003(4):28-29. 被引量:1
  • 2方贵银.热力膨胀阀的选配及故障排除[J].冷藏技术,1994,17(4):36-39. 被引量:1
  • 3陈文勇,陈芝久,陈佑华.冷柜启动过程中电子膨胀阀的控制[J].流体机械,2005,33(10):77-80. 被引量:2
  • 4马骏,汪晓钧,邹宗峰.变排量汽车空调系统结霜试验研究[J].机电一体化,2007,13(1):63-66. 被引量:4
  • 5魏跃文.[D].上海交通大学,2001.
  • 6Fuchs H V. Generation and control of noise in water supply installations Part 2: sound source mechanisms[ J]. Applied Acoustics, 1993, 38:59-85.
  • 7Amini , Owen I. A practical solution to the problem of noise and vibration in a pressure-reducing valve [ J ]. Experimental Thermal & Fluid Science, 1995,10( 1 ) :136-141.
  • 8Rodarte E, Miller N R, Hrnjak P,et al. Use of stereolithography as a design tool for developing quiet plate mobile air conditioning evaporators [ C]. 1998 SAE International Congress and Exposition, Detroit:1998.
  • 9Rodarte E, Miller N R, Hrnjak P. Refrigerant expansion noise propagation through downstream tube walls [ C ]. 1999 SAE International Congress and Exposition , Detroit:1999.
  • 10Rodarte E, Miller N R, Hmjak P. Noise generation from expansion devices in refrigerant[ C]. 1999 SAE International Congress and Exposition, Detroit : 1999.

共引文献75

同被引文献40

引证文献7

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部