期刊文献+

1000MW汽轮机润滑油压力低的原因分析及处理

Analysis on reasons of lower lubricating oil pressure of 1000 MW steam turbine and treatment
下载PDF
导出
摘要 某电厂1 000 MW机组启动过程中,汽轮机冲转至3 000 r/min时润滑油压力偏低,交流润滑油泵、启动油泵电流偏大。机组重新停运后进入汽轮机润滑油箱检查,发现主油泵出口至油涡轮增压泵入口管道堵头掉落,造成润滑油系统油涡轮增压泵出力不足。将堵头重新安装并固定后,机组启动汽轮机冲转至3 000 r/min时,润滑油系统各项参数正常。 In startup process of the 1 000 MW unit of a power plant,when the rotate speed of the turbine increased to 3 000 r / min,the lubricating oil pressure became lower,and the currents of the AC lubricating oil pump and the startup oil pump became larger. The unit was shut down for inspection. It was found by inspection inside the lubricating oil box that the plug of the inlet pipe of the oil turbine booster pump from the main oil pump outlet fell out,which caused the output of the oil turbine booster pump of the lubricating oil system to be insufficient. The plug was reinstalled and fixed,and the fault was eliminated.
作者 王海波
出处 《华电技术》 CAS 2015年第2期59-60,79,共2页 HUADIAN TECHNOLOGY
关键词 1 000 MW汽轮机 润滑油系统 压力 主油泵 油涡轮增压泵 堵头 1 000 MW steam turbine lubricating oil system pressure main oil pump turbine booster oil pump plug