冷却肋片对光伏板发电性能的影响研究 被引量:2

Study on effect of cooling fins on energy performance of photovoltaic panel
下载PDF
导出
摘要 研究了被动式冷却条件下肋片对光伏板发电性能的影响,分析了光伏板倾角、太阳辐射强度、环境温度和风速等因素对光伏板发电效率和发电功率的影响规律,对带冷却肋片和不带冷却肋片的光伏板进行了实验对比。研究结果表明,在实验条件下,安装冷却肋片可以使光伏板的发电效率提高0.3%~1.8%,发电功率提高1.8%~11.8%。 The performance improvement of PV panel with passive fin cooling was studied under natural ventilation.A comparative experimental study on PV panels with and without fin cooling was carried out to investigate the effect of PV panel inclination, solar radiation, and ambient temperature as well as wind velocity on the electrical efficiency and power output.The results showed the average electrical efficiency of PV panel with fins was 0.3%~1.8% higher than that of PV panel without fins and the average power output of PV panel with fins was 1.8%~11.8% higher as well under various conditions in this study.
出处 《可再生能源》 CAS 北大核心 2015年第3期346-350,共5页 Renewable Energy Resources
基金 北京市科技新星项目(2011029) 北京市青年拔尖人才项目(CIT&TCD201304067) 北京建筑大学校级学术创新团队项目(21221214104)
关键词 光伏板 被动式冷却 发电效率 冷却肋片 PV panel passive cooling electrical efficiency cooling fin
  • 相关文献

参考文献13

  • 1Skoplaki E,Palyvos JA. On the temperature dependence of photovoltaic module electrical performance: a review of efficiency/power correlations [J]. Solar Energy, 2009,83 (5) :614-624.
  • 2Assoa YB,Menezo C,Fraisse G,et al. Study of a new concept of photovohaic-thermal hybrid collector[J]. Solar Energy, 2007,81 (9) : 1132-1143.
  • 3M Chandrasekar, S Suresh, T Senthilkumar,et al. Passive cooling of standalone fiat PV module with cotton wick structures [J]. Energy Conversion and Management, 2013,71:43-50.
  • 4Yamawaki T,Mizukami S, Masui T,et al. Experimentalinvestigation on generated power of amorphous PV mod- ule for roof azimuth [J]. Solar Energy Materials and Solar Cells, 2001,67 (1-4) : 369-377.
  • 5Zondag H. Flat-plate PV-thermal collectors and systems: a review[J]. Renew Sust Energ Rev,2008,12 (4) :891 - 895.
  • 6Tobias I, delCanizo C, Alonso J. Handbook of Photovoltaie Science and Engineering [K]. Wiley:Antonio Luque and Steven Hegedus, 2003.
  • 7Chow T. Performance analysis of photovoltaie-thermal collector by explicit dynamic model [J]. Solar Energy, 2003,75(2) : 143-152.
  • 8Tiwari A,Sodha MS. Performance evaluation of a solar PV/T system: an experimental validation[J]. Solar Energy, 2006,80 (7) : 751-59.
  • 9Chow T,He W,Ji J. Hybrid photovohaic-thermosyphonwater heating system for residential application [J]. Solar Energy, 2006,80 (3) : 298-306.
  • 10Ji J ,Liu K,Chow T,et al. Performance analysis of a pho- tovoltaic heat pump [J]. Applied Energy, 2008,85 (8) : 680-693.

同被引文献20

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部