摘要
在梅山古雄工厂站铁路信号6502电气集中系统改造为计算机联锁集中控制系统项目中,对场间联系电路存在的问题进行了探讨。为确保国铁线路的作业安全,增加了场间特殊道岔同意操动联系电路;详细分析了道岔同意操动联系电路的技术要求及原理,并提出了实现方案。
This paper discussed the problems of inter-yard liaison circuit in the project of transforming the 6502 electric interlocking system into microcomputer interlocking system at Guxiong factory-owned railway station.In order to ensure the operation safety of state-owned railway lines,inter-yard special switch agree-to-operate liaison circuit was added.A detailed analysis of the principle and technical of the liaison circuit is made,and put forward the implementation scheme.
出处
《铁道通信信号》
2015年第2期46-48,共3页
Railway Signalling & Communication
关键词
铁路信号
场间联系
计算机联锁
Railway Signal
Field contact circuit
Microcomputer Interlocking System